beautypg.com

H. startup, H. startup warning, Fig. 5 – Hoshizaki DCM-300BAH(-OS) User Manual

Page 16

background image

16

H. Startup

WARNING

1. All parts are factory-adjusted. Improper adjustments may adversely affect

safety, performance, component life, and warranty coverage.

2. If the icemaker is turned off, wait for at least 3 minutes before restarting the

icemaker to prevent damage to the compressor.

3. At startup, confirm that all internal and external connections are free of leaks.

1) Open the water supply line shut-off valve.
2) Move the control switch to the "OFF" position. See Fig. 5.
3) Remove the front panel, then move the power switch to the "ON" position. Replace the

front panel in its correct position, then turn on the power supply.
Note: This unit will not run if the safety switch is not engaged.

4) Move the control switch to the "ICE" position to start the automatic icemaking process.
5) Once the unit starts to produce ice, allow it to run for another 30 minutes.
6) Move the control switch to the "DRAIN" position. Allow the water system to drain for

5 minutes.

7) Move the dispense mode switch to the "CONTINUOUS" position, then dispense all of

the ice from the storage bin.
Note: Ice dispenses continuously for a maximum of 60 seconds per activation.

8) Remove the front panel, then remove the storage bin cover.
9) Move the control switch to the "ICE" position.

10) Confirm bin control operation: Engage the safety switch on the front frame. See Fig. 5.

After the compressor starts, press and hold the actuator paddle located inside the
storage bin.

WARNING! Keep hands, hair, and loose clothing clear of the agitator

inside the storage bin. The icemaker should shut down within 10 seconds.

Fig. 5

Power Switch

Safety Switch

Actuator Paddle

Storage Bin Cover

Control Box Cover

CONTROL

DISPENSE MODE

4A1038-014

ICE

OFF

DRAIN

PORTION

CONTINUOUS