Sanitizing solution, Sanitizing procedure - initial – Hoshizaki FD-1001MRH(-C) User Manual
Page 39
39
3. Sanitizing Solution
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after
dilution.
Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 5 gal. (19 l) of warm water.
4. Sanitizing Procedure - Initial
1) Make sure the power supply is off and the water supply line shut-off valve is closed.
Remove the panels, then move the power switch to the "OFF" position.
2) Remove the strap connecting the spout to the chute assembly, then remove the spout.
Remove the rubber O-ring and nylon O-ring (if applicable) at the top of the cylinder and
also remove the packing between the spout and the chute.
3) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overflow into the drain pan.
4) Remove the proximity switch from the chute assembly, then remove the chute
assembly from the icemaker.
5) Remove the packing at the bottom of the ice chute. Remove the 3 ties and the chute
insulation.
6) Remove the 2 baffles.
7) Remove the plate and the packing from the top of the ice chute, then remove the
backup bin control assembly by sliding it slightly towards the chute opening and lifting it
off.
8) Disassemble the backup bin control assembly by removing the 2 snap pins, shaft, and
actuator.
9) Soak the spout, O-ring(s), packings, chute, baffles, plate, and backup bin control
assembly in the sanitizing solution for 10 minutes then wipe them down.
10) Rinse the parts thoroughly with clean water.
CAUTION
If the solution is left on these parts, they will rust.
11) Replace all parts in their correct positions.
IMPORTANT
When installing the baffles, make sure that the bent surface (the one without
the studs) faces the actuator so that the bent surface can guide the ice to the
center of the actuator.
12) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions, then turn on the power supply.
Make ice using the solution until the icemaker stops making ice.
13) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.