Icemaker, Fig. 14 – Hoshizaki FD-1001MRH(-C) User Manual
Page 27
27
1. Icemaker
• If you would like to convert to top water supply, install the optional Top Water Supply Kit
(HS-2123).
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD
copper tubing is recommended for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for
the icemaker drain line.
2-inch
(5-cm) air
gap
Floor
Drain
FD-1001MAH(-C)
FD-1001MRH(-C)
FD-1001MLH(-C)
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
Icemaker Water
Supply Line
Shut-Off Valve
Icemaker Water
Supply Line
Drain Valve
Icemaker
Icemaker Water
Supply Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Icemaker
Drain Outlet
3/4" FPT
To convert to top water supply,
install the optional Top Water
Supply Kit (HS-2123).
Storage Bin
Fig. 14