beautypg.com

Mechanical backup bin control check, Fig. 19 – Hoshizaki FD-1001MRH(-C) User Manual

Page 34

background image

34

2. Mechanical Backup Bin Control Check

1) Make sure the power supply is off.
2) Remove the strap connecting the spout to the chute assembly. See Fig. 19. Pull up the

chute assembly slightly so that you can access the actuator located in the top of the
chute.

3) Move the power switch to the "ON" position.
4) Turn on the power supply to start the automatic icemaking process.

5) Make sure the "GM" LED is on. See Fig. 14. There is a delay of at least 30 seconds

before the "GM" LED turns on after power-up. After the "GM" LED turns on, press
the "SERVICE" button on the control board to bypass the 5-minute compressor
delay.

WARNING! Risk of electric shock. Care should be taken not to touch live

terminals. The "COMP" LED turns on.

6) Press the actuator located in the top of the chute. The compressor and gear motor

should de-energize within 10 seconds and the control board should sound a 9 beep
alarm.

7) Turn the power switch off and then on again to reset the control board alarm.
8) After resetting the control board alarm, move the power switch to the "OFF" position

and turn off the power supply.

9) Replace the chute assembly and strap in their correct positions.

10) Move the power switch to the "ON" position.
11) Replace the control box cover, top panel, and front panel in their correct positions.
12) Turn on the power supply to start the automatic icemaking process.

Fig. 19

Chute Assembly

Actuator

Spout

Strap

Proximity Switch

Strap

This manual is related to the following products: