System communication – Honeywell ADEMCO LYNXR-EN User Manual
Page 55

–55–
System Communication
Report
3+1/4+1 Standard
3+1/4+1 Expanded
4+2
Alarm
SSS(S) A
SSS(S) A
AAA(A) Z
SSSS AZ
Trouble
SSS(S) T
SSS(S) T
TTT(T) t
SSSS Tt
Bypass
SSS(S) B
SSS(S) B
BBB(B) b
SSSS Bb
AC Loss
SSS(S) E
SSS(S) E
EEE(E) AC
SSSS EAC
Low Battery
SSS(S) L
SSS(S) L
LLL(L) LB
SSSS LLB
Open
SSS(S) O
SSS(S) O
OOO(O) U
SSSS OU
Close
SSS(S) C
SSS(S) C
CCC(R) U
SSSS CU
Test
SSS(S) G
SSS(S) G
GGG(G)g
SSSS Gg
Restore Alarm
SSS(S) R
SSS(S) R
RRR(R) Z
SSSS RZ
AC Restore
SSS(S) RA SSS(S)
RA
RARARA(RA)Ac
SSSSRA Ac
Low Battery Restore
SSS(S) RL SSS(S)
RL
RLRLRL(RL)LB
SSSS RLLB
Trouble Restore
SSS(S) RT SSS(S)
RT
RTRTRT (RT)t
SSSS RTt
Bypass Restore
SSS(S) RB
SSS(S) RB
RBRBRB (RB)b
SSSS RBb
ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where:
CCCC = Customer (subscriber) ID
Q =
Event qualifier, where: E = new event, and R = restore
EEE = Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual)
GG =
Always “00”
ZZZ =
Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System
status messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.
CONTACT ID® EVENT CODES
Code
Definition
110 Fire
Alarm
121 Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible
131 Alarm,
Perimeter
132 Alarm,
Interior
134 Alarm,
Entry/Exit
135 Alarm,
Day/Night
145
Wireless Dialer Tamper
(plus Zone 93) (Alarm)
146 Silent
Burglary
150
Alarm, 24-Hour Auxiliary
301 AC
Power
338
Wireless Dialer Low Battery
(plus Zone 93)
341
Wireless Dialer Tamper
(plus Zone 93)
(Trouble)
342*
Wireless Dialer AC Loss
(plus Zone 93)
344
RF Jam Detected
351*
Wireless Dialer Phone Line Cut
(plus Zone 93)
354
Fail to Report
355
Wireless Dialer Loss of RF Supervision
(plus Zone 93)
355
(Zone 000) Reported by the 5842 Wireless Dialer
373
Fire Loop Trouble
374
Exit Error Alarm
*If supported by the 5842 Wireless Dialer that is installed.
Code
Definition
380
Global Trouble, Trouble Day/Night
381
RF Supervision Trouble
383
RF Sensor Tamper
(Trouble)
384
RF Sensor Low Battery
401
Disarmed, Armed AWAY (NO DELAY),
Armed AWAY
403
Scheduled Auto Arm
406 Cancel
by
User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY/NO DELAY
441
Disarmed/Armed STAY/NO DELAY, Quick Arm
STAY/NO DELAY
570 Bypass
602 Periodic
Test
606
AAV to follow
607 System
Test
623
Event Log 80% Full
654 System
Inactivity
NOTE: The following codes are logged in the event log upon
occurrence, but are not reported:
305 = System Reset
627 = Keypad Program Mode Entry