Installation procedure, Other instruction and test – haier AE122BCAAA (H2EM-18H03) User Manual

Page 27

background image

26

Flarer

A

Pipe diameter

Dimension A(mm)

Connecting pipe

6.35mm(1/4")

0.8~1.5

12.7mm(1/2")

Installation procedure

Other instruction and test

Other instruction

Set of the air sending of the fan motor

Before leaving factory, the rotation speed of fan motor has already been set at standard choice.
When the indoor unit uses free air sending and not needing to connect with duct, the fan speed
of indoor unit is set at standard choice. When the indoor unit needs to connect with duct, please
according to the following figure shown to change the connection of the connector installed on
the side of electric box.

Standard air sending

(Before leaving factory)

High fan speed air sending

Connector(White)

White

Connector(White)

Cut and flaring method

The relative relation between

fan speed and static pressure

Unit: Pa

Standard

fan speed

High fan speed

Use pipe cutter to cut the pipe, the

burrs must be removed.

After inserting the flarer,

perform flared nut.

The following items must be noticed carefully during installation.
After finishing installation, performing checking.

After installing the refrigerant pipe, drain hose and electric wire properly,
perform test run to ensure the system not have trouble.

Test run

It is necessary the installer perform the test run for one time
to check if the unit works normally.

Liquid pipe

Gas pipe

Correct

Incorrect

Slant Broken Burrs Uncompleted Too long

1.0~1.0

0

30

Control box side

Control box side

Fan motor side

Fan motor side

Red