beautypg.com

Installation instruction, Installation of duct – haier AE122BCAAA (H2EM-18H03) User Manual

Page 17

background image

Installation instruction

1. Installation of Duct

2) Sectional shape of duct (mainly has rounded and rectangular two shapes)

16

3) Connecting mode

1)Duct material

Rectangular duct

The dimension of rectangular duct is the same as the air outlet of indoor unit,can be directly connected; the rounded
duct needs to be added with a static pressure box to connect with the air sending outlet of indoor unit; independently
introduced to respective distributor by rounded duct. In order to meet the requirements of room air conditioner,
the fan speed in each air outlet of any distributor shall be adjusted to basically the same.

Rounded duct

R=2.5d

d

b

a

a

b

R*3/2b

Number of duct outlet

Out unit static pressure (Pa)

Rectangular
duct

Diameter of dut*mm)

Noise dB(A)

Duct length (m)

Recommended applicable area(m )

Partial resistance of distributor(Pa)

1-2

30

700

100

200

Resistance along duct (Pa/m)

1.2

14*25

40/38/36

4

25

L(mm)

H(mm)

a

b
c

30

0

25

5

788

Air

volume(m/h)

Static pressure(Pa)

Speed

20

15

10

669

642

763

543

587

716

480

615

740

519

442

567

687

390

512

632

538

663

418

463

3

4) Installation parameter

Good processing performance and structural hardness

Main use

Structural characteristic

Material

Nonmetal

material

Type

Thin metal sheet

Air volume-static pressure graph of duct type unit

Glass fibre reinforced

plastic

2

Air volume-static pressure of duct type unit

Cutline

High speed

Medium speed

Low speed

High speed
Medium speed

Low speed

400

600

800

0

10

5

15

20

25

30

a

b

c

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Air volume(m/h)

*

*

*

Static pressure

value(Pa)

3

Aluminum orits alloy

Galvanize steel

Stainless steel

Generally used in ventilation duct system

Good anticorrosive performance

Storm protection system in
ventilation engineering

Good processing performance, corrosion resistant,
uneasily sparkle

Anticorrosive, acid-resistant

Anti-corrosive ventilation
engineering in chemical industry

Normal thin steel

Soft with compression resistant, simple installation
with vibration resistance

Sprayed a layer of 0.2~0.4mm plastic on the normal
thin steel

Widely used

Anti-corrosive, glazed surface, easy production

Aluminum foil soft

metal duct

Plastic compound steel

Stiff PVC plastic

Anti-corrosive, glazed surface, easy
production

With light, high intensity, noncombustible,

anti-corrosive, high temperature resistant characteristic

Air conditioning system needing
good dust protection and anti-
corrosive system under 10~70*

Applicable to the ambient condition
of 0*60 *,ventilation system
with corrosion of acid gas