Troubleshooting, Symptom cause – haier AE122BCAAA (H2EM-18H03) User Manual

Page 14

background image

13

If after the above checking and treatment, the air conditioner still cannot work normally, or
find the following phenomena, please stop the unit and contact the commissioned service
center.
The fuse or breaker is often blown out or open circuit.
In COOLING or DEHUMIDIFYING, there is water leakage.
Abnormal operation or abnormal sound be heard.
The display screen of the wire controller shows trouble code indicating the unit has
trouble.

F1

F2

Trouble Contents

Indoor temperature sensor trouble

F5

High pressure trouble (pressure)

F6

Drainage trouble

F4

Code Displayed

Inner pipe coil sensor trouble (thin pipe)

Troubleshooting

Before as the special repair center for help, please check the following items of the air

conditioner

Symptom

Cause

Hear the sound of

water flow

The water flow sound when operation starts; during operation and shortly
after operation stops, in 2-3 minutes shortly after the operation starts,
sometimes the sound becomes louder. This is the sound of refrigerant flow
and the draining sound of condensate water.

Not trouble

In DEHUMIDIFYING,

no air sent out or cannot

change the fan speed.

In DEHUMIDIFYING operation, when the room temperature is 2 C higher
than the set temperature, despite of the set FAN SPEED the air conditioner
will operate in LOW FAN SPEED.

Having peculiar smell

in the out air

Because the smells generated by wall, carpet, furniture,clothes, cigarette
and cosmetic, etc. attached on the air conditioner.

The stopped indoor unit

gives out sound, white

vapor or cold air.

In order to prevent the oil and refrigerant from resorting in the indoor
unit, there is refrigerant flow in very short time, so they give out ìSha,
Shaî, ìGulu, Guluî. Additionally, when the other indoor units perform
HEATING operation, sometimes white vapor appears; when the other
indoor units perform COOLING operation, cold air appears.

If there is the following symptom and check they are the following causes,
please solve them according to the below given methods.

Inner pipe coil sensor trouble (thick pipe)

Symptom

Causes

Solution

The unit does

not work

The fuse is blown out or the

breaker is open-circuit.

Change fuse or close breaker

Once the unit starts,

it stops immediately

The air inlet or outlet of indoor and

outdoor unit is blocked

Remove the obstacle

Remove the obstacle

The air inlet or outlet of indoor

and outdoor unit is blocked

Improper set temperature

The fan speed is set too low

Doors or windows are open

Direct sunshine. (COOLING)
Too much people in room (COOLING)

Too many heat sources in room (COOLING)

Refer to page 7

Refer to page 7

Close them

Hang curtains or blinds before window

Abnormal

COOLING or

HEATING