Models bbm/bbl, Nomenclature, Features – Heatcraft Refrigeration Products U User Manual

Page 7: Application, Back bar reach-in unit cooler

background image

7

Features

• Molded Lexan® fan guards

• Coils have copper tubes with aluminum fins, mechanically-

bonded for efficient heat transfer. The coils are dehydrated

and sealed

• Textured aluminum cabinet

• Knockouts are conveniently located for refrigerant lines

• Screws are hardened, stainless steel with a bright

zinc plating

• Expansion valve mounts inside the cabinet and

connections are sweat-type

• Motors are thermally protected and

permanently lubricated

• Master units include the basic unit plus factory mounted

expansion valve, solenoid, and temperature control. Also

right-hand piping extended 8” - 12” outside the housing,

sealed and pressurized to 20 - 30 PSI. A 1/4” OD liquid feed

to slave is included

• Slave units include the basic unit plus factory mounted

expansion valve with left-hand piping extended 8” - 12”

outside the housing, sealed and pressurized to 20 - 30 PSI

Sweat inlet connection to reduce leaks

(flare connection available as a ship loose option)

application

Models BB

are compact, wall-mounted units whose low

height makes them ideal for undercounter reach-in or drawer-

type fixtures. The unit draws air in at the bottom and discharges

out the front. An optional air deflector is included and can be

mounted over the center of the fan to direct air up and out. The

deflector can be field-formed to direct the air where needed,

usually onto drop-in trays of condiments in salad bar or sandwich

preparation fixtures. An S-type mounting angle is included

to position the unit 3/4” off the wall which gives optimum air

circulation and performance.
The BBM (medium temperature) model is designed for 35°

to 40°F fixture temperature with off-cycle defrost. The unit

is designed to operate at 10° to 17° TD and 16 hours per day

compressor run time.
The BBL (low temperature) model is designed for 0° to -10°F

fixture temperature, and has automatic electric defrost. The

unit is designed to operate at 8° to 15° TD with 18 hours per

day compressor runtime. The BBL has an incoloy sheath heater

embedded in the bottom fin surface for efficient and fast

defrosting. A drain pan heater is included to insure complete

condensate drainage. A disc-type sealed defrost termination/

fan delay control is mounted and wired. Field connectors are

located at the terminal board.

Models BBM/BBl

Back Bar Reach-In Unit cooler

Diagram 5. Dimensions

table 10. Physical Data

Model

Dimensions (in.)

approx.

ship Wt. (lbs.)

a

B

c

D

e

F

W

BBL10 19-1/8

18

17-1/2 7-1/16

-

16-5/8 19-3/4

17

BBM11 19-1/8

18

17-1/2 7-1/16

-

16-5/8 19-3/4

16

BBL15 25-5/8 24-1/2

24

4-13/16 8-5/8 23-1/8 26-1/4

20

BBM16 25-5/8 24-1/2

24

4-13/16 8-5/8 23-1/8 26-1/4

19

typical section of

sandwich station

Model BBM

NOTES: All units have 3/8” OD suction, 1/2” OD sweat inlet and 1/2” OD drain

table 9. Performance and electrical Data

Model

BtUh

10°F

tD

Motor Data

Defrost heaters

cFM Qty. hP 115/1/60

total Fla

08-

0/1/60

total Fla

Watts 115/1/60

amps

08-

0/1/60

amps

BBL10 1,000 90

1 1/150

0.8

0.4

275

2.7

1.4

BBM11 1,100 90

1 1/150

0.8

0.4

-

-

-

BBL15 1,500 180

2 1/150

1.6

0.8

350

3.5

1.7

BBM16 1,600 180

2 1/150

1.6

0.8

-

-

-

nomenclature

BB l s 10 a G

Voltage

a = 115/1/60

B = 08-0/1/60

Back Bar Unit cooler

size

l = low temp. Unit

M = Med. temp. Unit

Vintage

Blank = standard Unit

s = slave Unit

M = Master Unit