WARNING
1. All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
2. If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
3. To prevent damage to the water pump, do not leave the control switch in the
"WASH" position for extended periods of time when the water tank is empty.
4. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
5. At startup, confirm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve.
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel and the insulation panel.
7) Remove the rubber cap covering the overflow pipe in the water tank. Remove the
overflow pipe by turning it counterclockwise. Allow the water tank to drain. See Fig. 14.
8) Replace the overflow pipe, the rubber cap, the insulation panel, and the front panel in
their correct positions.
9) Clean the storage bin using a neutral cleaner. Rinse thoroughly after cleaning.
10) Turn on the power supply to start the automatic icemaking process.
11) When the icemaker is running, hold an ice cube in contact with the bulb. The icemaker
should stop within 10 seconds. Adjustment may be needed, particularly at higher
altitude locations.
Fig. 14
Rubber Cap