beautypg.com

Hoshizaki KM-1601MRH/3 User Manual

Page 11

background image

11

• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models, the white lead must be connected to the neutral conductor of the

power source.

CAUTION! Miswiring may result in severe damage to the icemaker. See

Fig. 4a.

• On three phase models, the transformer’s voltage tap switch must be positioned to match

incoming voltage at startup. See Fig. 4b.

CAUTION! On three phase models, connect the highest incoming voltage supply

("stinger leg") to the red power supply wire (red common wire to the compressor).

• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Fig. 4a

Fig. 4b

KM-1601MRH

KM-1601MRH3