beautypg.com

7 • troubleshooting – Hunter Fan UNIVERSAL FAN AND LIGHT REMOTE CONTROL 27188 User Manual

Page 10

background image

10

41797-01 • 07/06/10 • Hunter Fan Company

7 • Troubleshooting

Symptom

Possible Causes

Solution

1.No functions operate.

Main Power not restored.

Replace fuse. Turn ON circuit breaker. Turn ON wall switch.

Fan pull chain not set to High. Set fan pull chain to High speed.
Light pull chain not set to ON. Set light kit to ON.
Receiver wiring incorrect.

Verify wiring connections.

Transmitter and receiver DIP

switches do not match.

Set transmitter and receiver to same DIP switch setting.

Battery too weak.

Replace with new, 12 Volt alkaline battery. Refer to

“Transmitter Installation”, Section 6.

2.Operates only at close range. Signal blocked from reaching

receiver.

Extend antenna into ceiling box, or move it for better

reception.

Battery too weak.

Replace with new, 12 Volt alkaline battery. Refer to

“Transmitter Installation”, Section 6.

Interference

Change the DIP switch settings on the remote receiver and

transmitter,

3.Inconsistent operation.

Signal partially blocked from

reaching receiver.

Extend antenna into ceiling box, or move it for better

reception.

RF interference.

Turn OFF wall switch for 5 seconds, then turn back ON.

Continuing RF interference.

Change jumper settings to a different code in both transmitter

and receiver.

This manual is related to the following products: