W arning, Cautions, Step 1: removing wiring harness
41490-01 03/12/2009
INSTALLATION INSTRUCTIONS FOR HUNTER
CEILING FAN LIGHT KITS MODELS:
28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342
W ARNING
•
To avoid possible electrical shock, before in-
stalling light fixtur es, disconnect power by
turning of f the cir cuit breakers both to the
outlet box and to its associated wall switch
location. If you cannot lock the cir cuit break-
ers in the of f position, secur ely fasten a
prominent war ning device, such as a tag, to
the service panel.
Connect house wiring to the fan befor e at-
taching the light fixtur e to the fan.
All wiring must be in accor dance with na-
tional and local electrical codes and ANSI/
NFPA 70. If you ar e unfamiliar with wiring,
you should use a qualified electrician.
CAUTIONS
Read entire text carefully before beginning in-
stallation and save these instructions.
To r educe the risk of electrical shock, install
this light kit only on Hunter ceiling fan
models with removable switch housings.
STEP 1: REMOVING WIRING HARNESS
Before you can install the modular accessory light
kit, you must remove the wiring har ness and its com-
ponents fr om the modular switch housing on the
fans listed above. You must then install the wiring
harness into the modular accessory light kit.
NOTE: Refer to Figure 1 for the steps listed below.
1. Locate the r eversing switch and car efully remove
the two screws holding the reversing switch to
the switch housing. The r eversing switch can now
be removed from the switch housing.
2. Remove the patented br eakaway connector from
the fan pull chain.
3. Carefully loosen the bellmouth nut from the fan
pull chain and remove the fan pull chain switch
from the switch housing.
4. Locate and car efully remove the two capacitors
from the switch housing.
5. You have now disconnected the wiring har ness
and its components fr om the switch housing and
are ready to install them into the modular acces-
sory light kit.
STEP 2: INSTALLING WIRING HARNESS
NOTE: Refer to Figure 1 for steps listed below.
1. Locate the two wir es in the lower switch housing
labeled “Connect Light Here” or “For Light Use”.
One will be white, the other black with a white stripe.
Unscew the wire connectors counterclockwise
to expose the bare metal leads.
2. Locate the white wire and the black wire coming
from the light fixtur e.
Connect the black wir e fr om the light fixture to
the black wire with a white stripe from the
lower switch housing.
Connect the white wir e fr om the light fixture to
the white wir e from the lower switch housing.
To fasten the wir es, twist the two bare leads to-
gether. Place a wire connector over the intertwined
length of wire and twist clockwise until tight.
Fan Speed
Switch
Capacitor
Reverse Switch
Multi-wire Plug
Connection
Capacitor
Bellmouth Nut
M3 Housing
Assembly Screws
Light Kit Lead Wires
and Wire Connectors
FIGURE 1