VenTInG

Use Only Approved Venting

The.Clarity.gas.heater.is.tested.and.listed.for.connection.

to.a.4".(100.mm).listed.Class.B.venting.system..

If.the.unit.is.installed.to.vent.through.an.approved.masonry.

chimney.or.a.factory-built.chimney.system,.an.approved.

Class.B.chimney.liner.must.be.used..

Observe.local.codes.when.venting.the.Clarity..If.no.local.

codes.exist,.follow.the.current.edition.of.ANSI.Z223.1.and.

CAN1-.B149.installation.codes..

Do not connect the venting to the flue of a chimney that

serves.a.separate.solid-fuel.burning.appliance.

The.venting.manufacturer's.installation.instructions.must.

be.followed.exactly.

IMPORTANT: Because of the high efficiency and low

flue gas temperatures of this appliance, it is important that

it be connected to a well-sealed and efficient venting system

which.is.capable.of.registering.a.negative.pressure.while.

the.stove.is.in.operation.

The most efficient venting systems are those that have a

minimum.number.of.bends.and.minimal.horizontal.runs.

The.Clarity.gas.heater.is.equipped.with.a.thermally.acti-

vated.vent.safety.switch.that.will.shut.down.the.main.burner.

if.the.heater.is.not.properly.venting..The.safety.switch.will.

automatically.reset.after.the.heater.has.cooled.down.

The.switch.will.continue.to.cycle.off.and.on.until.the.

venting.problem.is.corrected..If.you.are.unable.to.correct.

the.venting.problem,.seek.expert.advice.from.your.Harman.

dealer.or.installer.

Do noT DIsConneCT oR bYPass THe VenT

safeTY sWITCH.

WARNING: Operation of this heater when not con-

nected to a properly installed and maintained venting

system or tampering with the vent safey shutoff system

can result in carbon monoxide (Co) poisoning and pos-

sible death.

The.Clarity.gas.heater.is.equipped.with.its.own.internal.

draft.hood.so.no.additional.external.draft.hood.is.required..

The.heater.should.be.installed.so.that.the.draft.hood.is.in.

the.same.atmospheric.pressure.zone.as.the.air.inlets.to.the.

heater.

TesT foR flUe sPIllaGe

A.spillage.test.should.always.be.made.at.the.completion.

of.the.installation.

1..Start.all.exhaust.fans.in.the.home.and.then.close.all.

doors.and.windows.in.the.room.containing.the.heater.

2..Light.the.heater.and.allow.it.to.run.for.5.minutes.on.the.

high.output.setting..If.the.convection.air.blower.is.installed,.

it.should.be.turned.off.for.the.test.

3..Hold.a.match.or.other.source.of.smoke.near.the.draft.

hood.outlet.on.the.upper.back.of.the.stove..

4..If.the.smoke.is.not.drawn.in,.turn.off.the.heater.and.

determine.the.cause.of.the.lack.of.draft..If.necessary,.seek.

expert.advice.

For.sites.with.swirling.or.turbulent.wind.conditions,.a.

wind.cap.may.solve.the.problem.