5700 act wood stove, Clearances to combustibles (ul and ulc) – Hearth and Home Technologies 820-0721 User Manual
Page 6

5700 ACT Wood Stove
Page 6
September 1, 2008
R
250-7090e
CLEARANCES TO COMBUSTIBLES (UL AND ULC)
A
b
C
D
BACkWALL / SIDEWALL
e
F
e
F
CORNER INSTALLATION
g
H
*
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
C
D
ALCOVE TOP VIEW
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches and (Millimeters)
NOTE: All “A”, “C” and “F” Dimensions are to the inside diameter of the flue collar.
A
b
C
D
e
F
g
H
INSTALLATION: Full Vertical OR Horizontal with 2 foot minimum vertical Off Stove Top
SINGLE WALL PIPE
12.5 (318) 8 (203) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 18 (457)
*
DOUBLE WALL PIPE
9.5 (241) 5 (127) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 12 (305)
INSTALLATION: 90
o
ELBOW OFF TOP OF STOVE THROUGH BACkWALL
DOUBLE WALL PIPE
9.5 (241) 5 (127) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 12 (305)
INSTALLATION: ALCOVE
Six inch (6") (152mm) diameter listed Double Wall air insulated connector
pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home
must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than
48"(1220mm) with a minimum height of 45.5" (1156mm) to top of unit, and the referenced
clearances.
DOUBLE WALL PIPE
10.5 (268) 6 (153) 25.5 (648) 15 (381) N/A
N/A 45.5 (1156)
**
*
NFPA MINIMUM CLEARANCES - NOT TESTED
**
SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
g
A
B
ALCOVE SIDE VIEW
SERIAL NUMBER / SAFETY LABEL LOCATION:
ON BACk OF STOVE