CLEARANCES TO COMBUSTIBLES (UL AND ULC)

A

b

C

D

BACkWALL / SIDEWALL

e

F

e

F

CORNER INSTALLATION

g

H

*

90° OFF TOP

UP & OUT CEILING

CLEARANCE

STOVE TO CEILING

CLEARANCE

C

D

ALCOVE TOP VIEW

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches and (Millimeters)

NOTE: All “A”, “C” and “F” Dimensions are to the inside diameter of the flue collar.

A

b

C

D

e

F

g

H

INSTALLATION: Full Vertical OR Horizontal with 2 foot minimum vertical Off Stove Top

SINGLE WALL PIPE

12.5 (318) 8 (203) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 18 (457)

*

DOUBLE WALL PIPE

9.5 (241) 5 (127) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 12 (305)

INSTALLATION: 90

o

ELBOW OFF TOP OF STOVE THROUGH BACkWALL

DOUBLE WALL PIPE

9.5 (241) 5 (127) 25.5 (648) 15 (381) 2 (51) 13 (432) 45.5 (1156) 12 (305)

INSTALLATION: ALCOVE

Six inch (6") (152mm) diameter listed Double Wall air insulated connector

pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home

must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than

48"(1220mm) with a minimum height of 45.5" (1156mm) to top of unit, and the referenced

clearances.

DOUBLE WALL PIPE

10.5 (268) 6 (153) 25.5 (648) 15 (381) N/A

N/A 45.5 (1156)

**

*

NFPA MINIMUM CLEARANCES - NOT TESTED

**

SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED

g

A

B

ALCOVE SIDE VIEW

SERIAL NUMBER / SAFETY LABEL LOCATION:

ON BACk OF STOVE