beautypg.com

5700 act wood stove, Ash removal system (ars) installation, Ars operating and cleaning – Hearth and Home Technologies 820-0721 User Manual

Page 15

background image

Page 15

September 1, 2008

5700 ACT Wood Stove

R

250-7090e

1. Place protective pad or stove pallet on floor.
2. Lay body of stove on its back on protective pad or pallet.
3. remove ash removal system top and bottom cover plates by

loosening nuts under stove.

Discard both plates

.

ASH REMOVAL SYSTEM (ARS) INSTALLATION

1. When stove is cool, open front door and brush most

of the ash into the center of the firebox. remember

to leave 1/4” to 1/2” (6-13mm) of ash on the firebox

floor to act as a natural grate, allowing air to flow

freely underneath wood.

2. Clean ash down through the ash removal system

grate into the drawer below. If there are large pieces

in the ashes, you can remove the grate before

brushing the ash into the drawer. be sure to replace

the grate before operating the stove.

3. Swing open ash removal door on leg model. (On the

pedestal model, first pull down the hinged pedestal

front to expose the ash removal door).

4. Pull out the ash drawer. CLOSe the ash removal

door. (Closing this door avoids ash blowing into the

room in the event of a downdraft).

5. empty the ashes following the directions below.
6. Swing open ash removal door and replace ash

drawer with the overhanging lip facing toward you.

7. Close ash removal door securely.

ARS OPERATING AND CLEANING

FIGURE 15b

4. Using a rubber mallet, install plugs (supplied) into two front

holes,

See Figure 15B.

5. Line up holes in ash removal system with holes in adapter on

bottom of stove.

6. Screw ash removal system securely in place.
7. Insert ashpan into ash removal system box, making sure

the overhanging lip is facing towards you.

8. Attach legs or pedestal.

CAUTION FOR NOTE LEG MODELS: DO NOT TILT THE

UNIT ON THE CAST IRON LEGS. Lift the unit upright and

place it into position on the floor protector.

9. After righting stove, insert ash removal system grate into

opening in firebox floor.

PEDESTAL MODEL

DISCARD

INSTALL PLUGS

INTO THESE TWO

HOLES

Ash Drawer

Pull down pedestal front

first

Disposal of Ashes. Ashes should be placed in a metal

container with a tight fitting lid. The closed container of

ashes should be placed on a non-combustible floor or

on the ground, well away from all combustible materials,

pending final disposal. If the ashes are disposed of by

burial in soil or otherwise locally dispersed, they should

be retained in the closed container until all cinders have

thoroughly cooled.

Ash Drawer

LEG MODEL

STOVe bOTTOM

NUTS

TOP COVer

PLATe

grATe

FIGURE 15A