5700 ACT Wood Stove

Page 2

September 1, 2008

R

250-7090e

and Welcome to the Quadra-Fire Family

!

H

earth & Home Technologies welcomes you to our tradition

of excellence! In choosing a Quadra-Fire appliance, you have

our assurance of commitment to quality, durability, and perfor-

mance.
This commitment begins with our research of the market,

including ‘Voice of the Customer’ contacts, ensuring we make

products that will satisfy your needs. Our research and Devel-

opment facility then employs the world’s most advanced tech-

nology to achieve the optimum operation of our stoves, inserts and

fireplaces. And yet we are old-fashioned when it comes to crafts-

manship. each unit is meticulously fabricated and surfaces are

hand-finished for lasting beauty and enjoyment. Our pledge to qual-

ity is completed as each model undergoes a quality control inspec-

tion. We wish you and your family many years of enjoyment in the

warmth and comfort of your hearth appliance. Thank you for choos-

ing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: On right side of insert as face the appliance

Model

Name

Serial

Number

Test Lab &

Report No

.

A

B

C

D

E

F

G

H

SINGLE WALL PIPE

12.5 (318) 8 (203) 25.5 (648) 15 (381)

2 (51)

13 (330) 45.5 (1156) 18 (457)

**

DOUBLE WALL PIPE

9.5 (241) 5 (127) 25.5 (648) 15 (381)

2 (51)

13 (330) 45.5 (1156) 12 (305)

DOUBLE WALL PIPE

9.5 (241) 5 (127) 25.5 (648) 15 (381)

2 (51)

13 (330) 45.5 (1156) 12 (305)

INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT* listed factory-built

Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48

inches (1220mm) with a minimum height of 45.5 inches (1156mm) to top of unit, and the referenced clearances.

(*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650

o

C Factory-built chimney.)

(*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650

o

C cheminée bâtit en usine.)

DOUBLE WALL PIPE

10.5 (268) 6 (153) 25.5 (648) 15 (381)

N/A

N/A

45.5 (1156)

***

**

NFPA MINIMUM CLEARANCES - NOT TESTED

***

SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe
"A:, ou une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS:

In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.

LISTED ROOM HEATER, SOLID FUEL TYPE.

ALSO FOR USE IN MOBILE HOMES. (UM)

84-HUD .

"For Use with Solid Wood Fuel Only"

1445 N. Highway, Colville, WA 99114

www.quadrafire.com

Install and use only in accordance with

manufacturer's installation and operating

instructions. Contact local building or fire officials

about restrictions and installation inspections in

your area. Do not obstruct the space beneath

heater.

WARNING - For Mobile Homes: Do not install in

a sleeping room. An outside combustion air inlet

must be provided and unrestricted while unit is in

use. The structural integrity of the mobile home

floor, ceiling and walls must be maintained. The

stove needs to be properly grounded to the frame

of the mobile home. Components required for

mobile home installation: Outside Air Kit, Part

Number 831-1780.

Refer to manufacturer's instructions and local

codes for precautions required for passing

chimney through a combustible wall or ceiling and

maximum offsets.

Inspect and clean chimney frequently - Under

Certain Conditions of Use, Creosote Buildup May

Occur Rapidly.

Do not connect this unit to a chimney serving

another appliance.

Optional Components: Optional Blower, Part

831-1701.

Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.

Route power cord away from unit. Do not route

cord over or in front of appliance.

DANGER: Risk of electrical shock. Disconnect

power supply before servicing.

Replace glass only with 5mm ceramic available

from your dealer.

Do not use grate or elevate fire. Build wood fire

directly on hearth.

Do not overfire - if heater or chimney connector

glows, you are overfiring.

Operate only with the fuel loading door closed.

Open only to add fuel to the fire.

CAUTION

:

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to

comply with July 1990 particulate emission standards.

2007 2008 2009 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.

PREVENT HOUSE FIRES

FLOOR PROTECTION

:

Floor protector must be a 1/2 inch min. thickness, ("k" value =

.84) non-combustible material or equivalent, extending beneath

heater and to front/sides/rear as indicated on the diagram

below. Exception: Non-combustible floor protections must

extend beneath the flue pipe when installed with horizontal

venting and extend 2 inches (51mm) beyond each side.

O-T L

Tested and

Listed by

Beaverton

Oregon USA

OMNI-Test Laboratories, Inc.

C

Report / Rapport

#061-S-38-2

TESTED TO:/ TESTÉ À:

UL 1482, ULC S627-93

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP

FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

VENT SPECIFICATIONS:

SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or

blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air

insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or
Security DL double wall connector pipe. Must be equipped with a spark arrestor.
Apply double wall clearances below when installing unit.

5700 Step Top

R

250-7072E

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT

PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR

L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

A

PPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE

COMBUSTIBLE SOLIDE, POUR USAGE DANS LES

MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec

Bois Solide Seulement"

Installez et utilisez en accord avec les instructions

d'installation et d'opération du fabricant. Contactez le

bureau de la construction ou le bureau des incendies au

sujet des restrictions et des inspections d'installation dans

votre voisinage. Ne pas obstruez l'espace en dessous de

l'appareil.

AVIS - Pour Les Maisons Mobiles: Ne pas installer dans

une chambre à coucher. Un tuyau extérieur de

combustion d'air doit être installé et ne doit pas être

obstrué lorsque l'appareil est en usage. La structure

intégrale du plancher, du plafond et des murs de la

maison mobile doit être maintenue intacte. L'appareil de

chauffage doit être fixé à la charpente de la maison

mobile. Les composants requis pour l'installation des

maisons mobiles: Assemblage d'air extérieur, Numéro de

Pièce 831-1780.

Référez vous aux instructions du fabricant et des codes

locaux pour les précautions requises pour passer une

cheminée à travers un mur ou un plafond combustibles,

et les compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. Sous

certaines conditions, il se peut que la créosote

s'accumule rapidement.

Ne pas connecter cet appareil à une cheminée servant un

autre appareil.

Composants Optionnels: Ventilateur Optionnel, Pièce

#831-1701.

Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer

le fil électrique au dessus ou en dessous de l'appareil.

DANGER: Il y a risque de décharge électrique.

Déconnectez le fil électrique de la prise de contact avant

le service.

Remplacez la vitre seulement avec une vitre céramique

de 5 mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement

sur l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau

de cheminée rougissent, vous surchauffez.

Opérez l'appareil seulement lorsque la porte de

chargement est fermée. Ouvrez la porte seulement

lorsque vous devez ajouter des combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON

PROTECTION DU PLANCHER:

Le protecteur de plancher doit être d'un minimum de 1/2 inch

d'épaisseur, ('k" value = .84) de matériel incombustible ou

équivalent, s'étendant du dessous de l'appareil de chauffage

à l'avant, aux cotés et à l'arrière comme indiqué sur le

diagramme suivant. Exception: Les protections

incombustibles du plancher doivent s'étendre en dessous du

conduit de cheminée lorsqu'installées avec une ventilation à

l'horizontale et s'étendre de 2 inches (51mm) de chaque côté.

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:

En Pouces & (millimètres)

NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur

de l'entrée du conduit.

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ

90 OFF TOP

UP & OUT CEILING CLEARANCE

ESPACE LIBRE DU DESSUS DE

L'APPAREIL AU PLAFOND AVEC 90 DE

COURBURE

STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU PLAFOND

CORNER INSTALLATION

INSTALLATION DU COIN

ALCOVE TOP VIEW /

VUE DU HAUT DE L'ALCÔVE

ALCOVE SIDE VIEW /

VUE DE CÔTÉ DE L'ALCÔVE

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A./Fait Aux États-Unis

CONDUIT DU MUR SIMPLE

CONDUIT DU MUR DOUBLE

INSTALLATION: 90

o

ELBOW OFF TOP OF STOVE THROUGH BACKWALL

INSTALLATION: 90

o

DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE

INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine

UL103HT de Classe "A", ou une cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve

ne doit pas être de plus de 48 inches (1220mm) avec une hauteur minimum de 45.5 inches (1156mm) du haut de l'appareil, et des espaces libres alloués.

CONDUIT DU MUR DOUBLE

A

B

C

D

E

F

E

F

G

H

C

D

G

A

B

16" from glass

8"

USA

Fuel loading door

3-3/16”

4-3/16”

33-5/8”

minimum

44-9/16”

minimum

CANADA

203mm (8")

203mm

(8")

203mm

(8")

457mm (18")

1387mm

(54-9/16")

minimum

1083mm (42-5/8")min

Manufactured by:

Fabriqué par:

"G" is from top

where flue is

connected

INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP

INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

CONDUIT DU MUR DOUBLE

SERIAL NO. / NUMÉRO DE SÉRIE

007

Size: 8-1/2” x11

Copy: Red & Black

Background: Silver

Material: Foil w/slit back

Mfg Date