beautypg.com

5700 act wood stove – Hearth and Home Technologies 820-0721 User Manual

Page 17

background image

Page 17

September 1, 2008

5700 ACT Wood Stove

R

250-7090e

bLOWer SPeeD CONTrOL

blower

Mounting

Flange

Outer

Skin

INSTALLATION OF OPTIONAL BLOWER, Part 831-1701

The blower is shipped fully assembled and ready for installation.

NOTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise

to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.

1. With the unit plugged in, turn the speed control knob to slow (full clockwise).
2. With a small screwdriver, adjust the blower speed by turning the adjustment mechanism through the hole on the side

of the speed control.

3. Adjust the speed so the blower runs slowly, but does not stop. Turn clockwise to slow the blower and counterclockwise

to increase the speed.

*The blower speed control for this unit is adjusted at the factory and normally does not

require further adjustment.

1. remove the three bolts (1/4”-20 Phillips Head) on the outer skin at the bottom rear of stove.
2. Align holes in mounting flange of blower with bolt holes in stove. blower should be positioned around bottom of rear outer

skin as shown in drawing below.

3. re-insert and tighten bolts, securing blower onto outer wall of stove.

Do not remove ground from plug.

Plug blower cord into a grounded outlet. route power cord away from stove in such a

manner to avoid heat from the stove, traffic, or other damage. Do not route cord under or in front of stove.

ADJUSTING THE BLOWER SPEED CONTROL, IF NECESSARY*

FIGURE 17A