Specifications – HP 3500yl Series User Manual
Page 7
7
ProCurve Switch 5400zl/3500yl Series
Specifications
Included accessories
Ports
Power supplies
Physical characteristics
Dimensions (D x W x H)
Weight
Memory and processor
Gigabit module
10G module
Management module
Mounting
Performance
Latency
1000 Mb
10 Gbps
Throughput
Routing/Switching capacity
Switch fabric speed
Routing table size
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage
relative humidity
Altitude
Acoustic
Electrical characteristics
Description
Maximum heat dissipation
Voltage
Frequency
Notes
Safety
Emissions
Immunity
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
ProCurve Switch 5406zl Intelligent Edge (J8697A)
N/A
6 open module slots
1 RS-232C DB-9 console por t
Suppor ts a maximum of 144 auto-sensing 10/100/1000 por ts or
24 10-GbE por ts or 144 mini-GBICs, or a combination
2 open power-supply slots
45.09 x 44.45 x 17.53 cm (17.75 x 17.5 x 6.9 in.) (4U height)
10.68 kg (23.55 lb.)
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB
compact flash, 256 MB DDR SDRAM
<3.7 µs (FIFO 64-byte packets)
<2.1 µs (FIFO 64-byte packets)
Up to 214 million pps
288 Gbps
346 Gbps
10,000 entries
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or
J8707A modules installed
15% to 95% @ 55°C (131°F), non-condensing
–40°C to 70°C (–40°F to 158°F)
15% to 95% @ 65°C (149°F), non-condensing
Up to 4.6 km (15,000 ft.)
Power: 57 dB; pressure: 40.2 dB
ISO 7779, ISO 9296
Chassis ships without power supplies. Two power-supply slots available;
two different power supplies available. See power-supply products for
additional specifications.
2,584 kJ/hr (2,450 BTU/hr) (max non-PoE)
3,903 kJ/hr (3,700 BTU/hr) (max using PoE)
100–127 VAC/200–240 VAC
50/60 Hz
Power supplies must be ordered separately. One J8712A or J8713A can
power the J8697A chassis.
Heat dissipation does not include heat dissipated by the PoE powered
devices themselves.
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
ProCurve Switch 5406zl-48G Intelligent Edge (J8699A)
2 ProCurve Switch zl 24-Por t 10/100/1000 PoE Modules (J8702A)
1 ProCurve Switch zl 875W Power Supply (J8712A)
4 open module slots
48 auto-sensing 10/100/1000 por ts (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T) with PoE
Media type: IEEE Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console por t
Suppor ts a maximum of 144 auto-sensing 10/100/1000 por ts with PoE or
16 10-GbE por ts or 96 mini-GBICs, or a combination
Includes 1 x J8712A
1 open power-supply slot
45.09 x 44.45 x 17.53 cm (17.75 x 17.5 x 6.9 in.) (4U height)
15.54 kg (34.26 lb.)
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash,
256 MB DDR SDRAM
<3.7 µs (FIFO 64-byte packets)
<2.1 µs (FIFO 64-byte packets)
Up to 214 million pps
288 Gbps
346 Gbps
10,000 entries
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or
J8707A modules installed
15% to 95% @ 55°C (131°F), non-condensing
–40°C to 70°C (–40°F to 158°F)
15% to 95% @ 65°C (149°F), non-condensing
Up to 4.6 km (15,000 ft.)
Power: 57 dB; pressure: 40.2 dB
ISO 7779, ISO 9296
One J8712A installed. One open power-supply slot available; two different
power supplies available. See power-supply products for additional
specifications.
2,584 kJ/hr (2,450 BTU/hr) (max non-PoE)
3,903 kJ/hr (3,700 BTU/hr) (max using PoE)
100–127 VAC/200–240 VAC
50/60 Hz
Heat dissipation does not include heat dissipated by the PoE powered
devices themselves.
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal sur face mounting only
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A