Appliance location and clearances, Warning, Caution – Heat & Glo Fireplace TIARAP-CES User Manual
Page 7
August 1, 2008
Page 7
Heat & Glo · Tiara Petite B · 7026-101K
3
Appliance Location and Clearances
A. Selecting Appliance Location
NOTE:
·
Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
·
Illustrations/diagrams are not drawn to scale.
·
Actual installation may vary due to individual design
preference.
When selecting a location for your appliance it is important to
consider the required clearances to wall (see
Figure 3.1).
Figure 3.1
B. Clearances to Combustibles
Model
A
B
C
D
E
F
G
H
Tiara
Petite B
Inches
6
2
2
43
36
30
20-1/4
19-1/2
Millimeters
152
51
51
1092
914
762
527
495
A
B
F
E
A
"A"
measurement is from
stove top, not side
C
C
A
G
-
Alcove
A
D
H
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings
• To
combustibles
• For
service
access
Locate appliance away from traffi c areas.
NOTE: For actual appliance dimensions refer to
Section 12.
Fire Risk.
• Locate and install appliance to all
clearance specifi cations in manual.
WARNING
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
It is permissable to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
Fire Risk.
Odor Risk.
Tipping Risk
• Install appliance on a stable, level platform/
fl oor strong enough to support appliance
without tipping.
• USE
wood
fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.
WARNING