beautypg.com

Caution, D. ignition module access and battery replacement, Shock hazard. • replace damaged wire with type 105 – Heat & Glo Fireplace TIARAP-CES User Manual

Page 30

background image

Page 30

August 1, 2008

Heat & Glo · Tiara Petite B · 7026-101K

Figure 7.1

Figure 7.2

D. Ignition Module Access and Battery
Replacement

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Black

Black

Ignition Module

Switch

ON/OFF

O

FF

PIL

O T

ON

T

P

T

H

T

P

T

H

LO

H

I

E

A

P ILO

T

PILOT ASSEMBLY

VALVE

TH

TP

TPTH

Thermopile

Gas Pilot Igniter

Thermocouple

The single "AA" 1.5V battery that powers the ignitor is
located in the module. To replace the battery, open the
battery compartment and remove the old battery. Replace
the battery making sure the polarity is correct.

1.

Lift off the appliance top and place it on a fl at surface,
with the porcelain side up to prevent damage.

2.

Remove the appliance front by sliding it upwards in the
grooves, being careful not to chip the porcelain. Lay the
front face up on a fl at surface.

3.

With the cast iron front removed, remove the decorative
cover located under the apliance. To remove the cover,
remove the two screws on the front of the appliance that
hold the cover in place. Pull the cover forward, down
and out. The module will then be accessible for service
and battery replacement.

The Ignition Module is located under the appliance attached
to the decorative cover.

To access the module:

Shock hazard.
• Replace damaged wire with type 105

O

C

rated wire.

• Wire must have high temperature insulation.

CAUTION

CAUTION

Battery polarity must be correct or module damage will occur.

This manual is related to the following products: