Page 13
12
MSSC, LLC Collinsville, IL USA
Tel: 618-343-1006
Fax: 618-343-1016
55899
Rev 18210
www.msscllc.com
Setup Menu
To access the setup menu press the STUP key.
Ink
This sub menu allows the user to specify the ink cartridge volume as well as when the QM2 generates a
low ink alarm.
To set the ink volume:
1. Press STUP key
2. Select INK and press
↵.
3. Use the
↑ and ↓ keys to change highlighted field.
4. Type in the desired value, 42 ml for a new cartridge or 370 ml for the bulk ink system.
5. Then set ink low at desired setting to generate low ink alarm. Press 02 for 2ml alarm trigger, for
example.
6. When done press
↵ to save the changes and return to the previous menu.
Parameter
The PARAMETER sub menu is used to setup how the QM2 prints the selected message. The settings
in this menu can be unique to each message or set up as common parameters.
Note: When a parameter is changed from the common settings; an asterisk (*) will appear next to the
message number. To revert back to the common settings return to the parameter submenu and press the
asterisk (*) key. This will restore all parameters for the selected message to the settings under
COMMON.
•
MSG: Select the message number to alter. If COMMON is selected, the settings will apply to
all messages that do not have a custom setting.
•
DELAY: Sets the distance between when the photo eye is tripped and the start of printing. This
value can be set from 0 to 999mm (0 to 39.3in). NOTE: 25mm = 1in.
•
WIDTH: Sets the width of the characters printed. This value can be set from 2 to 26mm (0.08 to
1.02in). The range of acceptable values is dependent on the SPEED and DENSITY settings.
•
HEIGHT: Sets the height of the characters printed. This value can be set from 5 to 13 mm (0.2 to
0.51in).
•
DENSITY: Controls the amount of ink deposited. A lower value means less ink and a lighter
print. A higher value means more ink and a darker mark. The range of acceptable values is 1 to 8
dependent on the SPEED and WIDTH settings.
•
FONT: Sets the font used in the message. There are two different fonts shown below.
•
DIRECT: Sets the direction of conveyor travel as well as mark orientation.
•
SPEED: Sets the QM2 for the speed the conveyor runs at. This value can be set from 1 to
60m/min (3 to 200ft/min).