Isle royale wood stove, Warning – Hearth and Home Technologies QUADRA-FIRE 823-0170 - MBK User Manual
Page 7
Isle Royale Wood Stove
R
March
21,
2013
250-5763F
Page
7
Exterior conditions such as roof line, surrounding trees,
prevailing winds and nearby hills can influence stove
SHUIRUPDQFH
WKDWZLOOHDVLO\FRUUHFW\RXUÀXHSUREOHP
D. Flue Dra t Considerations
/RFDWLRQ RI WKH DSSOLDQFH DQG FKLPQH\ ZLOO DIIHFW SHUIRU-
PDQFH $V VKRZQ LQ Figure .1 on page the chimney
should:
%HLQVWDOOHGWKURXJKWKHZDUPVSDFHHQFORVHGE\WKH
building envelope. This helps to produce more draft,
HVSHFLDOO\GXULQJOLJKWLQJDQGGLHGRZQRIWKH¿UH
3HQHWUDWHWKHKLJKHVWSDUWRIWKHURRI7KLVPLQLPL]HV
the affects of wind turbulence and down drafts.
&RQVLGHU WKH DSSOLDQFH ORFDWLRQ LQ RUGHU WR DYRLG
ÀRRUDQGFHLOLQJDWWLFMRLVWVDQGUDIWHUV
E. Venting Systems
The venting system consists of a chimney connector (also
known as stove pipe) and a chimney. These get extremely
hot during use. Temperatures inside the chimney may
exceed 2000
qF (1100q&LQWKHHYHQWRIDFUHRVRWH¿UH7R
SURWHFWDJDLQVWWKHSRVVLELOLW\RIDKRXVH¿UHWKHFKLPQH\
connector and chimney
must be properly installed and
maintained.$QDSSURYHGWKLPEOHPXVWEHXVHGZKHQD
connection is made through a combustible wall to a chimney.
$FKLPQH\VXSSRUWSDFNDJHPXVWEHXVHGZKHQDFRQQHFWLRQ
is made through the ceiling to a prefabricated chimney.
These accessories are
absolutely necessary to provide
safe clearances to
combustible wall and
ceiling material.
Follow venting manufacturer’s clearances when installing
venting system.
To be sure that your appliance burns properly, the chimney
draft (static pressure) should be approximately -.04 inch water
column (W.C.) during a low burn and -.10 inch W.C. during a
high burn, measured 6 inches (152mm) above the top of the
appliance after one hour of operation at each burn setting.
NOTE: These are guidelines only, and may vary somewhat
for individual installations.
F. Tools And Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Reciprocating saw
Pliers
Hammer
Phillips Head Screwdriver
Flat Blade Screwdriver
3OXPE/LQH
/HYHO
Tape Measure
Framing Material
Hi-Temp Caulking Material
Gloves
Framing Square
(OHFWULF'ULOO %LWV´
Safety Glasses
1/2 in. - 3/4 in. length, #6 or
#8 self drilling screws (need 3
per pipe section connection)
G. Inspect Appliance & Components and
re Burn Check List
1.
3ODFHWKHDSSOLDQFHLQDORFDWLRQQHDUWKH¿QDO
installation area and follow the procedures below:
2.
Open the appliance and remove all the parts and
articles packed inside the Component Pack. Inspect
all the parts and glass for shipping damage. Contact
your dealer if any irregularities are noticed.
3.
$OOVDIHW\ZDUQLQJVKDYHEHHQUHDGDQGIROORZHG
4.
This Owner’s Manual has been read.
5.
Floor protection requirements have been met.
6.
Venting is properly installed.
7.
The proper clearances from the appliance and
chimney to combustible materials have been met.
8.
The masonry chimney is inspected by a professional
and is clean, or the factory built metal chimney is
installed according to the manufacturer’s instruc-
tions and clearances.
9.
The chimney meets the required minimum height.
10.
$OOODEHOVKDYHEHHQUHPRYHGIURPWKHJODVVGRRU
11.
$ SRZHU RXWOHW LV DYDLODEOH QHDUE\ LI LQVWDOOLQJ
optional blower assembly.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
WARNING
'R127LQVWDOOGDPDJHGFRPSRQHQWV
'R127LQVWDOOLQFRPSOHWHFRPSRQHQWV
'R127LQVWDOOVXEVWLWXWHFRPSRQHQWV
Report damaged parts to dealer.
Fire Risk.
WARNING
'2127&211(&77+,681,772$&+,0-
1(<)/8(6(59,&,1*$127+(5$33/,-
$1&(
'2127&211(&772$1<$,5',675,%8-
7,21'8&7256<67(0
0D\DOORZÀXHJDVHVWRHQWHUWKHKRXVH
Asphyxiation Risk.