250-5763F
March
21,
2013
Isle Royale Wood Stove
The Quadra-Fire Isle Royale Wood Stove meets the U.S.
(QYLURQPHQWDO3URWHFWLRQ$JHQF\¶VSDUWLFXODWHHPLV-
sion standards.
$$SSOLDQFH&HUWL¿FDWLRQ
&*ODVV6SHFL¿FDWLRQV
'%78 (I¿FLHQF\6SHFL¿FDWLRQV
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
(3$&HUWL¿HG
2.9 grams per hour
(I¿FLHQF\
76.5%
BTU Output:
11,500 to 46,000
Heating Capacity:
2,040 to 3,500 sq ft
depending on climate zone
Vent Size:
6 inches
Firebox Size:
3.0 cubic feet
Max Wood Length:
22 inches
Fuel:
Cord Wood
Shipping Weight:
480 lbs
Model:
Isle Royale
Laboratory:
201,7HVW/DERUDWRULHV,QF
Report No & Date:
061-S-18-2
Type:
/LVWHG5RRP+HDWHU6ROLG)XHO7\SH
Standard:
8/8/8/&6
and (UM) 84-HUD, Mobile Home
$SSURYHG
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the
8/8/
80+8'DQG13)$LQWKH86$DQGWKH8/&6
DQG&$1&6$% Installation Codes in Canada.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
WKHLUVSHFL¿FDWLRQVDQGRUSULFHZLWKRXWQRWLFH
,PSURSHU LQVWDOODWLRQ DGMXVWPHQW DOWHUDWLRQ VHUYLFH RU
PDLQWHQDQFHFDQFDXVHLQMXU\RUSURSHUW\GDPDJH
)RUDVVLVWDQFHRUDGGLWLRQDOLQIRUPDWLRQFRQVXOWDTXDOL¿HG
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
,QVWDOODWLRQDQGXVHRIDQ\GDPDJHGDSSOLDQFH
0RGL¿FDWLRQRIWKHDSSOLDQFH
,QVWDOODWLRQRWKHUWKDQDVLQVWUXFWHGE\+HDUWK +RPH
Technologies.
,QVWDOODWLRQDQGRUXVHRIDQ\FRPSRQHQWSDUWQRW
approved by Hearth & Home Technologies.
2SHUDWLQJDSSOLDQFHZLWKRXWIXOO\DVVHPEOLQJDOO
components.
2SHUDWLQJDSSOLDQFHZLWKRXWOHJVDWWDFKHGLIVXSSOLHG
with unit).
'R1272YHU¿UH,IDSSOLDQFHRUFKLPQH\FRQQHFWRU
JORZV\RXDUHRYHU¿ULQJ
$Q\VXFKDFWLRQWKDWPD\FDXVHD¿UHKD]DUG
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
B. Mobile Home Approved
This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
7KHVWUXFWXUDOLQWHJULW\RIWKHPRELOHKRPHÀRRUFHLO-
ing, and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
use only listed double-wall connector pipe.
2XWVLGH$LU .LW SDUW PXVW EH LQVWDOOHG LQ D
mobile home installation.
1
Listing and Code Approvals