Installing the Fireplace

Step 1. Locating the Fireplace

The diagram below shows space and clearance require-

ments for locating a fireplace within a room.

A

B

C

D

E

42”

22”

36”

51”

72”

Minimum Clearances

from the Fireplace to Combustible Materials

Inches

mm

Glass Front ........................ 36 .................... 914

Floor ................................... 0 ....................... 0

Rear ...................................1/2 ..................... 13

Sides .................................1/2 ..................... 13

Top ................................... 3 1/2 ................... 89

Ceiling* .............................. 31 .................... 787

Figure 2. Fireplace Dimensions, Locations,

and Space Requirements

Clearance Requirements
The top, back, and sides of the fireplace are defined by

stand-offs. The minimum clearance to a perpendicular wall

extending past the face of the fireplace is one inch (25 mm).

The back of the fireplace may be recessed 21 1/2 inches

(546 mm) into combustible construction.

Minimum Clearances

from the Vent Pipe to Combustible Materials

Inches

mm

Vertical Sections. ............. 1 ................ 25
Horizontal Sections

Top ..................................... 3 ................ 75

Bottom ............................... 1 ................ 25

Sides ................................. 1 ................ 25
At Wall Firestops

Top .................................. 2 1/2 ............ 63.7

Bottom .............................. 1/2 ............... 13

Sides ................................. 1 ................ 25

* The clearance to the ceiling is measured from the top

of the unit, excluding the standoffs (see Figure 35).

The distance from the unit to combustible construction

is to be measured from the unit outer wrap surface to

the combustible construction, NOT from the screw heads

that secure the unit together.

For minimum clearances, see the direct vent termination

clearance diagrams on pages 22 and 23 in this manual.