Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed

electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-

SENT FOR EXTENDED TIME PERIODS. THIS WILL

PREVENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
•
This appliance DOES NOT require 110-120 VAC to operate.

WARNING: DO NOT CONNECT 110-120 VAC

TO THE GAS CONTROL VALVE OR THE AP-

PLIANCE WILL MALFUNCTION AND THE

VALVE WILL BE DESTROYED.

!

!

Figure 30. Standing Pilot Ignition Wiring Diagram

Figure 31. Fan Wiring Diagram

Optional Accessories
Optional fan and remote control kits require that 110-120

VAC be wired to the factory installed junction box before

the fireplace is permanently installed.

Remote Wall Switch
Position the remote wall switch in the desired position on a

wall. Run a maximum of 25 feet (7.8 m) or less length of 18

A.W.G. minimum wire and connect it to the fireplace ON/

OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC

TO THE REMOTE WALL SWITCH OR THE

CONTROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-

TION WHEN SERVICING CONTROLS. WIRING ERRORS

CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

VERIFY PROPER OPERATION AFTER SERVICING.

FAN

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

JUNCTION BOX

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.

O

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

GAS VALVE

BLACK S1

THERMOPILE

WHITE T2

TH TP

TP

TH

RED T1

OPTIONAL REMOTE

OPTIONAL WALL SWITCH

BLACK S2