beautypg.com

Heat & Glo Fireplace Heat-n- Glo BE-41 User Manual

Page 22

background image

22

V

=VENT TERMINAL

X

=AIR SUPPLY INLET

1234

1234

1234

1234

=AREA WHERE TERMINAL IS NOT PERMITTED

* 30” minimum for vinyl clad soffits.

** a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family

dwellings and serves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.

NOTE: Local codes or regulations may require different clearances.

Figure 25. Vent Termination Minimum Clearances

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS NECESSARY TO INSTALL THE VINYL

PROTECTOR KIT TO THE TOP OF THE EXTERIOR FIRESTOP (FOR ALL ROUND TERMINATION CAPS).

A

= 12" .................... clearances above grade, veran-

da, porch, deck or balcony

B

= 12" .................... clearances to window or door

that may be opened

C

= 9" (U.S.A.)

12" (Canada) ..... clearance to permanently

closed window.

*D

= 18" .................... vertical clearance to ventilated

soffit located above the termi-

nal within a horizontal distance

of 2 feet (60 cm) from the cen-

ter-line of the terminal

*E

= 18" .................... clearance to unventilated soffit

F

= 9" ..................... clearance to outside corner

G

= 6" ...................... clearance to inside corner

H

= 3 ft. (Canada) .... not to be installed above a gas

meter/regulator assembly with-

in 3 feet (90cm) horizontally from

the center-line of the regulator

I

= 3 ft. (U.S.A.)

6 ft. (Canada) ..... clearance to service regu-

lator vent outlet.

J

= 9" (U.S.A.)

12" (Canada) ..... clearance to non-mechan-

ical air supply inlet to

building or the combustion

air inlet to any other ap-

pliance

K

= 3 ft. (U.S.A.)

6 ft. (Canada) ..... clearance to a mechanical

air supply inlet

**L = 7 ft. ................... clearance above paved

sidewalk or a paved drive-

way located on public

property

***M = 18" .................... clearance under veranda,

porch, deck or balcony

D

E

B

L

v

v

v

v

v

v

v

v

openable

C

B

B

B

fixed closed

A

H

M

X

J or K

I

A

G

F