Temperature Settings
Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owners Guide, form number 69-1073, for complete
instructions on changing the program.
Table 2. Default Program Settings.
—
To advance to the next Installer Setup, press the Time
▲
▲
key.
—
To change a setting, use the increase
▲
or decrease
▼
key.
—
To scroll the Installer Setup numbers backwards,
press the Time
▼
▼
key.
—
To exit the Installer Setup, press Run Program.
Period
Time
Heat
Setpoint
Cool
Setpoint
Fan
Setting
Wake
6:00 AM
70°F
(21°C)
78°F
(25.5°C)
Auto
Leave
8:00 AM
62°F
(16.5°C)
85°F
(29.5°C)
Auto
Return
6:00 PM
70°F
(21°C)
78°F
(25.5°C)
Auto
Sleep
10:00 PM
62°F
(16.5°C)
82°F
(28°C)
Auto
Fig. 9. Display of all the segments of the LCD.
Aux Ht
Heat
Auto
System
Fan
Off
Auto
Wake
Mon
Wait
In
Room
Outdoor
%Humid
Auto
Sav
AM
PM
Hold for
Cool
Repl Batt
On
Recovery
DST
Cool
TueWedThuFriSatSun
LeaveReturnSleep
M10345
Set Program
Set Day/Time
Start Time
Temporary Setting Enrg
Em Heat
Em Ht
M10349
INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2
OF TABLE 3)
FACTORY SETTING
OR OTHER CHOICE
DISPLAY (COLUMN 3
OR 5 OF TABLE 3)
Fig. 10. Display of Installer Setup number and setting.
IMPORTANT
Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not
be displayed. Review Table 3 factory-settings
and mark any desired changes in the Actual
Settings column. When Installer Setup is
complete, review the settings to confirm that
they match the system.
INSTALLER SETUP
NOTE:
For most applications, the thermostat factory-
settings will not need to be changed. Review the
factory settings in Table 2 and if no changes are
necessary, go to the Installer Self-Test section.
The Installer Setup is used to customize the thermostat to
specific systems. Some of the options include temperature
display, changeover and outdoor temperature display.
Installer Setup numbers are listed in Table 3. The table
includes all the configuration options and the factory-
settings for the T8624.
A combination of key presses are required to use the
Installer Setup feature.
—
To enter the Installer Setup, press and hold the
Information
i
key with the increase
▲
and decrease
▼
keys until the first number is displayed. All display
segments appear for approximately three seconds
before the number is displayed. See Fig. 9 and 10.