background image

Maximum Network

Maximum Network

Maximum Network

Maximum Network
Interface Cards

Interface Cards

Interface Cards

Interface Cards (see
supported I/O table)

1000Base SX

10

1000Base TX

10

10/100Base TX

10

Dual port X.25

10

Electrical Characteristics

Electrical Characteristics

Electrical Characteristics

Electrical Characteristics

AC Input power

100 240V 50/60 Hz

Hotswap Power supplies

2 included, 3rd for N+1

Redundant AC power inputs

2 included, 3rd for N+1

Typical current requirements at
230V

5 A (shared across inputs)

Typical maximum power
dissipation

952 Watts

Theoretical maximum power
dissipation

2,089 Watts

Power factor at full load

0.98

Typical Heat dissipation
(BTUs/hour)

3,250

Maximum Heat dissipation
(BTUs/hour)

7,135

Site Preparation

Site Preparation

Site Preparation

Site Preparation

Site planning and installation
included

No

Depth (in/mm)

30.5 in (774 mm)

Width (in/mm)

19 in (482 mm)

Rack Height (EIA/in/mm)

7 U/12.25 in/322 mm

Pedestal Height (in/mm)

14.5 in (368 mm)

Weight (lb/kg) Maximum

161 lb (73 kg)

Environmental

Environmental

Environmental

Environmental
Characteristics

Characteristics

Characteristics

Characteristics

Acoustics (operator/bystander)
at 77° F/25° C)

<7.5 Bels LwA

Operating Temperature
(up to 5000 ft/1524 m)

1

41° to 95° F (5° to 35° C)

Non-operating Temperature

-40° to 158° F (-40° to 70° C)

Maximum rate of temperature
change

10° C/hour

Operating relative humidity

15% to 80% RH non-condensing

Non-operating relative
humidity

5% to 90% non-condensing

Operating altitude above sea
level

1,0000 ft (3,000 m) maximum

Non-operating altitude above
sea level

1,5000 ft (4,600 m) maximum

1

Max operating temperature range up to 5000 ft. For higher altitudes de rate the max temperature by 2°C/1000 ft above 5000 ft.

Regulatory Compliance

Regulatory Compliance

Regulatory Compliance

Regulatory Compliance

Electromagnetic

Complies with FCC Rules and Regulations, Part 15 as a Class A digital device.

Interference

Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL