Fig. 12. L7224/L7248 multizone system with Outdoor Reset and Domestic Hot Water Modules (indirect tank

applications).

M32024

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD

PROTECTION AS REQUIRED.

OPTIONAL FEATURE ON SELECT MODELS.

REFER TO DEVICE LABEL FOR WIRE COLOR CODE.

VALVE IS OPTIONAL ON SPECIFIED MODELS.

ENVIRACOM™ TERMINAL 3 IS ALSO THE FIRST THERMOSTAT TERMINAL.

1

2

3

C1

B1

ZC

L2

LINE

C2

ZR

L1

B2

T
T 3

2
1

SENSOR

LINE

VOLTAGE

CIRCULATOR

L7224

3

4

3

3

5

BURNER

MOTOR

IGNITOR

VALVE

BURNER

MOTOR

IGNITOR

VALVE

CAD

CELL

JUNCTION

BOX

TO REMOTE

ALARM

CIRCUIT

ENVIRACOM™

TERMINAL

R7184

LIMIT

L1

L2

2

CAD

CELL

T

T3

2

1

L1

(HOT) L2

1

LEGEND

SCREW TERMINAL

1/4 IN. (6 MM) QUICK CONNECT TERMINAL

SOLDERLESS WIRE CONNECTION

OPTIONAL OUTDOOR RESET MODULE AND OUTDOOR SENSOR.

OPTIONAL DOMESTIC HOT WATER MODULE.

WIRE ONLY THE ENVIRACOM TERMINALS (1, 2, 3) ON OIL PRIMARY

IF CONNECTING TO REMOTE DIAGNOSTICS, OTHERWISE CONNECT

A JUMPER BETWEEN THE TT TERMINALS.

ZONE PANEL TERMINALS MAY HAVE DIFFERENT LABEL. CHECK

PANEL MANUFACTURER SPECIFICATIONS FOR WIRING INSTRUCTIONS.

6

7

8

1 2 3 TS TS

32003971-003

TEMPERATURE

SENSOR

7

50022037-002

DOMESTIC HOT

WATER MODULE

9

MULTI-ZONE

RELAY PANEL

T T

4

5

1 2 3 OT OT

C7089U

OUTDOOR

SENSOR

6

50022037-002

OUTDOOR

RESET MODULE

8

9

This manual is related to the following products: