beautypg.com

Hoshizaki F-330BAH(-C) User Manual

Page 13

background image

13

13) Plug the unit back in. Move the control switch to the "ICE" position and move the power

switch to the "ON" position. Replace the panels in their correct positions and allow the
unit to make ice using the solution until it stops automatically.
Note: This unit is designed to start operating when the water reservoir is full.

14) Remove the front panel.
15) Move the control switch to the "DRAIN" position to drain the remainder of the solution.
16) After the solution has drained, move the control switch to the "ICE" position.
17) Replace the front panel in its correct position.
18) Open the water supply line shut-off valve to supply water to the reservoir.
19) When the gear motor starts, remove the front panel and move the control switch to the

"DRAIN" position to drain out the water from the icemaker.

20) After the water has drained, move the power switch to the "OFF" position and unplug

the unit.

Note: If you do not sanitize the icemaker, leave the unit plugged in with the power

switch in the "ON" position and go to step 18 in "5. Sanitizing Procedure - Final."

3. Sanitizing Solution

Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach)
with 5 gallons (19 l) of warm water.

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after
dilution.

4. Sanitizing Procedure - Initial

1) Close the water supply line shut-off valve.
2) Remove the top panel. Remove the bin control assembly from the top insulation and set

it aside. Remove the top insulation.

3) Remove the thumbscrews attaching spout (B) to the bin, then remove spout (B).
4) Remove the thumbscrews attaching spout (A) to the

evaporator assembly, then remove spout (A). Remove spout
packing (A) and the cylinder packing. See Fig. 4.

5) Pour the sanitizing solution over the extruding head until

the evaporator assembly and the reservoir are filled and the
solution starts to overflow into the drain pan.

6) Lift up slightly on the clip securing the bin control switch to

the paddle assembly and slide the switch out. See Fig. 5.

7) Soak the spouts, packings and paddle assembly in the

sanitizing solution for 10 minutes then wipe them down.

8) Rinse the parts thoroughly, then replace all parts in their

correct positions.

9) Plug the unit back in. Move the control switch to the "ICE" position and move the power

switch to the "ON" position. Replace the panels in their correct positions and allow the
unit to make ice using the solution until it stops automatically.

Clip

Bin Control
Switch

Paddle
Assembly

Fig. 5