beautypg.com

C. chimney components – Hearth and Home Technologies A42R User Manual

Page 43

background image

43

C. Chimney Components

The following pictures show only those chimney components which may be safely used with this fi replace.

ID4 Insulated Duct

UD4 Uninsulated Duct

42 in.

(1067 mm)

4 in. (102 mm) i

42 in.

(1067

)

4 in. (102 mm) i

Heatilator • A36R & A42R • 28376 • Rev AF • 11/08

CAK4A

Chimney Air Kit

ID4

Insulated Duct/Outside Air

UD4

Uninsulated Duct/Outside Air

SL306

Chimney Section - 6 in. (152 mm) long

SL312

Chimney Section - 12 in. (305 mm) long

SL318

Chimney Section - 18 in. (457 mm) long

SL324

Chimney Section - 24 in. (610 mm) long

SL336

Chimney Section - 36 in. (914 mm) long

SL348

Chimney Section - 48 in. (1219 mm) long

SL3

Chimney Stabilizer

SL315

Chimney Offset/Return - 15 deg

SL330

Chimney Offset/Return - 30 deg

FS338

Ceiling Firestop - Straight

FS339

Ceiling Firestop - 15 deg

FS340

Ceiling Firestop - 30 deg

AS8

SL300 Straight Attic Insulation Shield, 24 in. (610 mm)

JB877

Chimney Joint Band

CB876

Chimney Bracket

RF370

Roof Flashing - Flat to 6/12 Pitch

RF371

Roof Flashing - 6/12 to 12/12 Pitch

TR344

Round Termination Cap

TR342

Round Telescoping Termination Cap

ST375

Square Termination Cap

TS345

Square Termination Cap

TS345P

Square Termination Cap - Painted

TCT375

Terra Cotta Termination Cap

CT35

Chase Top

LDS33

Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)

LDS46

Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)

LDS-BV

Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm)

Field Constructed Shrouds (See “Woodburning
Termination Cap”)

CT-3A

Adapter - May be used with the following copper caps

CT-King

CT-Queen

CT-Bishop-I

CT-Bishop-II

CT-Knight-I

CT-Pawn

Catalog #

A

B

in

mm

in

mm

SL306

6

152

4-3/4

121

SL312

12

305

10-3/4

273

SL318

18

457

16-3/4

425

SL324

24

610

22-3/4

578

SL336

36

914

34-3/4

883

SL348

48

1219

46-3/4

1187

CAK4A Chimney Air Kit

SL3 Vent Stabilizer

Chimney Sections

A = Actual Length
B = Effective Length (length of

chimney part after it has
been snapped to another)

8 in.

(203 mm)

10-1/2 in.

(267 mm)

A

B

20-3/4 in.

(527 mm)

Inside

Diameter

8 in.

(203 mm)

Outside

Diameter

10-1/2 in.

(267 mm)

4-3/4 in. (121 mm)

Effective Height

10-1/2 in.

(287 mm)

12 in.

(305 mm)

5-1/4 in.

(133 mm)

4 in. (102 mm)

12 in.

(305 mm)

This manual is related to the following products: