Marginal Location:
• Below peak

Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended Location:
• Above peak

Recommended:
• Insulated exterior chase

in cooler climates

Recommended Location:
• Above peak
• Inside heated space

Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall

Marginal Location:
• Wind loading possible

Figure 5.2 Recommended Chimney Locations

E. Locating Fireplace & Chimney

Location of the fi replace and chimney will affect perfor-
mance.

• Install through the warm airspace enclosed by the

building envelope. This helps to produce more draft,
especially during lighting and die-down of the fi re.

• Penetrate the highest part of the roof. This minimizes

the effects of wind loading.

• Locate termination cap away from trees, adjacent

structures, uneven roof lines and other obstructions.

• Minimize the use of chimney offsets.
• Consider

the

fi replace location relative to fl oor and ceiling

and attic joists.

• Take into consideration the termination requirements in

Section 8 and Section 9.

NOTICE: Locating the fi replace in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from fi replace. Do not locate fi replace near
• frequently open doors
• central heat outlets or returns

Heatilator • A36R & A42R • 28376 • Rev AF • 11/08