Framing & Clearances

F

E

D

B

C

Across a
corner

G

As a
room
divider

A

48 in.

(1219 mm)

minimum

B

Along a wall

B

A

5/8 in. (16 mm) all
configurations

G

3/4 in. (19 mm) min. air
space from fireplace to
combustible materials. 1/2
in. (13 mm) allowed at
nailing flanges.

Note:

Note: In addition to these

framing dimensions, also
reference the following
sections:
• Clearances (Section

6.B.)

• Mantel Projections

(Sections 11.E. & 11.F.)

• Fireplace Dimensions

(Section 13.A.)

G

A

In an exterior chase
or projecting into a
garage

B

Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.

H

H

H

Figure 6.1 Fireplace Locations (Framing dimensions shown)

A. Select Fireplace Location

Model #

A

B

C

D

E

F

G

H

A36

in.

51

43

74 7/8

35 3/4

15 3/4

53

23

12 in. (305 mm)

Minimum from FP

opening to any

perpendicular wall.

mm

1295

1092

1902

908

400

1346

584

A42

in.

57

49

77 1/2

38 7/8

18

54 7/8

23

mm

1448

1245

1969

987

457

1394

584

Heatilator • A36R & A42R • 28376 • Rev AF • 11/08