beautypg.com

Initial installation – Enviro C-11089 User Manual

Page 22

background image

Initial Installation

QUALIFIED INSTALLERS ONLY

vent terminal (refer to Figure 40). Slide the Ø2”

(51mm) flex intake liner over the collar, secure the

flex liner with three (3) sheet metal screws evenly

spaced.

9. Make a tight connection between the gas fireplace

insert flue collar and the fireplace chimney at the

top of the chimney. Secure the vent terminal to the

chimney using adequate sealant, and according to

local building codes.

10. Light the Sonnet and ensure proper operation

and proper flame appearance. The amount of air

to the venturi may need to be adjusted using the

rod under the firebox (see Figure 7). Also refer

to Figure 77 for a flame appearance picture.

2" (51mm) Air Inlet

3" (76mm) Exhaust

Figure 40: Vertical Vent Cap Underside.

18"

(457mm)

18"

(457mm)

Trim flashing

as required.

Figure 39: Vertical Vent Cap Dimensions.

3. Install the flex pipe assembly up through the chimney, ensure that the pipe slides through far enough

to connect onto the Vertical Vent Cap.

Note: For any chimney over 15’ (4.6m), install the Sonnet 15’ 2” & 3” Flex Vent (part #50-1512)

and the Sonnet 2” & 3” Flex Couplers (part #50-1513). Place a bead of sealant on the coupler (Mill-

Pac Black sealant for the Ø3” (76mm) and high temperature silicone for the Ø2” (51mm)) Slide the

meeting ends of the flex over the coupler and fasten each joint in place with three (3) sheet metal

screws through the flex and into the coupler.

4. The Vertical Vent Cap can be installed onto chimneys with flue openings up to 16” (406mm) x 16”

(406mm) and the actual flashing is 18”x18” (refer to Figure 39). If the chimney is smaller the cap

should be trimmed down and folded over.

5. Apply a bead of Mill-Pac Black sealant to the top section of the Ø3” (76mm) vent collar plate. Slide

the Ø3” (76mm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly

spaced.

Note: If the fireplace opening is lower than 19” (483mm), remove the vent collar plate from the top

of the insert and connect it securely to the liner as stated in Step 4. Check for tears in the liner at this

point.

6. Place a bead of high temperature

silicone on the intake collar of the

fireplace, slide the Ø2” (51mm) flex

intake liner over the collar, secure the

flex liner with three (3) sheet metal

screws evenly spaced.

7. At the top of the chimney, apply a bead

of Mill-Pac Black sealant to the Ø3”

(76mm) pipe of the vent terminal (refer

to Figure 40). Slide the flex liner onto

the vent terminal and secure with three

(3) sheet metal screws evenly spaced.

8. Place a bead of high temperature

silicone on the intake collar of the

22

This manual is related to the following products: