Maintenance and service – Enviro C-11089 User Manual
Page 13
13
Sonnets are to be installed, confirm that the remote control signal codes are
different for each unit.To change the code, complete the following:
1. Change DIP switch position (shown at the top of Figure 13).
2. Press and hold the receiver’s reset button (see Figure 14) until you hear
two (2) acoustic signals. After the second longer acoustic signal, release
Maintenance And Service
C
HANGING
R
EMOTE
H
ANDSET
C
ODE
:
A code is preset for the remote handset and receiver, but can be changed if required. If one or more
Figure 13: DIP Switch in
Remote Handset Battery
Compartment.
Figure 14: Receiver with Reset Button.
the reset button and within the
subsequent 20 seconds, press
the (down arrow) on the remote
handset until you hear an additional
long acoustic signal confirming the
new code is set. The access hole for
the reset button is located on the left
side of the unit 8
7
/
16
” (214mm) back
from the front edge of the cabinet.
R
EMOVING
V
ALVE
C
OVER
:
The valve cover can be removed to access the gas valve, the fan, wiring harness, or other components.
1. Remove the glass door as shown in the M
AINTENANCE
AND
S
ERVICE
- G
LASS
D
OOR
R
EMOVAL
.
2. Carefully remove the log set, ember material, and brick panels, refer to S
ECONDARY
I
NSTALLATION
- B
RICK
P
ANEL
I
NSTALLATION
and S
ECONDARY
I
NSTALLATION
- L
OG
S
ET
AND
E
MBER
I
NSTALLATION
.
3. Using a T-20 screwdriver remove the two (2) screws that hold the burner tray in place (pointed out in
Figure 15). Pick up the burner tray at the front (see Figure 16) then pull it out of the firebox.
4. Using a T-20 screwdriver remove the six (6) screws that hold the valve cover in place (pointed out in
Figure 17). Pick the valve cover up then out of the firebox (see Figure 18).
Figure 15: Screws Holding Burner Tray in Place.
Figure 17: Screws Holding Valve Cover in Place.
Figure 16: Removing Burner Tray.
Figure 18: Removing Valve Cover.