beautypg.com

Rs-232c specifications and commands, Rs-232c specifications and, Commands – Eiki EIP-250 User Manual

Page 59: Computer control, Communication conditions, Basic format

background image

57

Info

• When controlling the projector using RS-232C commands from a computer, wait for at least 30

seconds after the power has been turned on, and then transmit the commands.

• After sending an input selection or picture adjustment command and then receiving an “OK” re-

sponse code, the projector may take some time to process the command. If a second command is
sent while the projector is still processing the first command, you may receive an “ERR” response
code. If this happens, try resending the second command.

• When more than one code is being sent, send each command only after the response code for the

previous command from the projector is verified.

• “POWR????” “TABN _ _ _ 1” “TLPS _ _ _ 1” “TPOW _ _ _ 1” “TLPN _ _ _ 1” “TLTT _ _ _ 1”

“TLTM _ _ _ 1” “TLTL _ _ _ 1” “TNAM _ _ _ 1” “MNRD _ _ _ 1” “PJN0 _ _ _ 1”
- When the projector receives the special commands shown above:

* The on-screen display will not disappear.
* The “Auto Power Off” timer will not be reset.

- The special commands are available for applications that require continuous polling.

Computer control

A computer can be used to control the projector by connecting an RS-232C serial control
cable (cross type, commercially available) to the projector. (See page

24

for connection.)

Communication conditions

Set the serial port settings of the computer to match that of the table.
Signal format: Conforms to RS-232C standard.

Parity bit: None

Baud rate*: 9,600 bps / 115,200 bps

Stop bit: 1 bit

Data length: 8 bits

Flow control: None

*Set the projector’s baud rate to the same rate as used by the computer.

Basic format

Commands from the computer are sent in the following order: command, parameter, and
return code. After the projector processes the command from the computer, it sends a re-
sponse code to the computer.

RS-232C Specifications and Commands

Return code (

0DH

)

C1 C2 C3 C4 P1 P2 P3 P4

Response code format

Normal response

Problem response (communication error or incorrect command)

O K

E R R

Command 4-digit

Parameter 4-digit

Command format

Return code (

0DH

)

Return code (

0DH

)

Note

• If an underbar (_) appears in the parameter column, enter a space.
• If an asterisk (*) appears in the parameter column, enter a value in the range indicated in brackets

under Control Contents.

*1 For setting the projector name, send the commands in the order of PJN1, PJN2 and PJN3.
*2 This command should be sent only after the “IRGB _ _ _ 2” command is sent and an “OK” response

code is received.

*3 The Lamp Timer Reset command is available only in standby mode.