beautypg.com

Limits for horizontal clusters only – Electro-Voice EVF/EVH EVF-1151S User Manual

Page 46

background image

Electro-Voice EVF/EVH User Manual

46

6.0 Rigging-Strength Ratings and Safety Factors (cont’)

6.5 HRK Rigging Structural Ratings for Horizontal Clusters

The guidelines for simplified horizontal structural ratings cover the following information:

1.

Maximum height of the cluster.

2.

Maximum weight of the cluster.

3.

Cluster combinations, per weight and height.

4.

Using tie plates for suspension.

5.

Suspension-line angles for HRK rigging.

6.

Symmetry of cluster.

7.

Inner connection points.

8.

Left-to-right horizontal cluster angles.

Using the HRK horizontal rigging kits, any combination of EVF and EVH enclosures can be assembled in

a cluster as long as the WLL, angles, and height limits are observed. For horizontal clusters, left-to-right

symmetry must also be observed to keep even loads across suspension lines.

Table 13:

Maximum load and maximum height for horizontal clusters

LIMITS FOR HORIZONTAL CLUSTERS ONLY

Maximum Working Load Limit

Maximum Height

Three-over-Three = 980 lb (445 kg)

Two-over-Two = 634 lb (288 kg)

Max. Two Enclosures High

or 5.25 ft (160.1 cm)

Table 14 gives a brief guide to the cluster combinations possible within the WLL of the EVF and EVH

enclosures.

Table 14:

Possible horizontal cluster combinations within the WLL of each enclosure

LIMITS FOR HORIZONTAL CLUSTERS ONLY

Clustered Enclosures

Maximum Number

of Enclosures

Minimum No. of

Suspension Lines

Tie Plate Angle

Restrictions

Three enclosures over

three enclosures

6

4

(2 per side)

See Figure 32

Two enclosures over

two enclosures

4

2

See Figure 32

Three enclosures across

3

4

(2 per side)

See Figure 32

Two enclosures across

2

2

See Figure 32

SUSPEND HORIzONTAL CLUSTERS USING TIE PLATES ONLy, NO EyEBOLTS.