beautypg.com

Configurations of terminals, En-33, Terminal : d-sub 9-pin service port connector – Eiki EIP-S200 User Manual

Page 34

background image

EN-33

Symptom
Remote control
doesn’t work.

Cause
The battery could be weak.
The remote control is not being
used within the effective range.
There are some obstructions
between the remote control and
projector.
There are some fluorescent or
other bright lights shining at the
projector’s infrared remote
sensor.

Solution
Replace with a new battery.
Use the remote control within
the effective range.
Check that there are not
obstructions between the
remote control and projector.
Check that there are not any
fluorescent or other bright lights
shining at the projector’s
infrared remote sensor.

Terminal : D-sub 9-pin

SERVICE PORT CONNECTOR

---

RX1A

TX1

---

GND

---

---

---

Serial

1

2

3

4

5

6

7

8

9

COMPUTER INPUT/COMPONENT INPUT TERMINAL (ANALOG)

Terminal : Analog RGB (Mini D-sub 15 pin)

5

1

2

3

4

10

9

6

7

8

15

14

13

11

12

Red (R/Cr) Input / Output

Ground (Horiz.sync.)

Green (G/Y) Input / Output

-----

Blue (B/Cb) Input / Output

Ground (Red)

Ground (Green)

Ground (Blue)

1

5

2

4

3

6

7

8

5V

Horiz. sync. Input/Output (Composite H/V sync.)

DSUB_PLUG

DDC data

-----

Vert. sync.

DDC clock

9

13

10

12

11

14

15

---

1

2

3

4

8

9

7

6

5

Configurations of Terminals