Extron Electronics WP CTL D User Manual
Wp ctl d installation guide, Wp ctl d installation guide, cont’d, Gs ir g rx tx serial
1.
Using a mud ring or a junction box as a guide, mark the holes and cut out the
material within the marked area.
N If installing a junction box, allow enough depth for
the wall plate and cables.
The box should be at least 2.0” (5.1 cm) deep to
accommodate the connectors, plate, and cables.
2
. Either
• Insert the mud ring into the opening, rotate
the dog legs, and secure with the screws provided,
or
• Insert the wall box and secure with 10-penny nails
or screws.
3.
Run the RS-232 and IR signal cables behind the wall
and thread them through the mud ring or wall box.
N
Extron recommends using a good quality, low
capacitance, shielded cable such as an Extron
CTL or SPL Control cable.
Decora
Faceplate
Extron
WP CTL D
Wall
Wall Mounting
Bracket
G
S
IR
G
Rx
Tx
Serial
WP CTL D Installation Guide
The Extron WP CTL D is a Decora style 1-gang wall plate which passes RS-232 control signals
from a computer or control system, and IR signals from an IR source.
Install it directly into the wall using a mud ring, or in a 1-gang junction box (not supplied),
following the steps below.
4.
Connect the IR cable to the rear panel IR
connector by inserting the signal wire into
the hole marked "S" , and the ground wire
into the hole marked "G" (see inset, step 4).
N
The recommended driving distance from
an MLC controller is 100 feet.
5.
Connect the RS-232 cable to the rear panel RS-232
connector by inserting the ground wire into the hole
marked "G", the transmit wire into the hole marked
"Tx", and the receive wire into the hole marked
"Rx" (see inset, step 5).
6
. Mount the device into the mud ring or wall box.
7
. Attach the supplied Decora faceplate.
N
If applicable, repeat steps 1-7 to install additional wall plates.
8
. Connect the RS-232 control device and/or IR input device to the front of the WP CTL D.
Extron
USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron
USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron
Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron
Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron
China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron
Dubai
+971.4.2991800
+971.4.2991880 FAX
68-1618-01
Rev B 08 08
WP CTL D Installation Guide, cont’d
Step 5
Step 4
G
Tx
Rx
WP CTL D
IR Out
White striped wire
S = Signal (IR)
G = Ground
G S
IR Emitter
100'
(30.5 m)