Design Specifications

ANTI-TIP BLOCK

NORMAL INSTALLATION STEPS

ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS

To reduce the risk of tipping the drawer, the anti-tip

block must be properly installed 14

13

/

16

" above the floor

cutout. The 6" anti-tip block must be provided by the

installer. See Figures 2 and 6 for (24") or Figures 4, 5,

and 6 (for 30"). The anti-tip block prevents serious injury

that might result from spilled hot liquids.

If the drawer is moved to a different location later, the

anti-tip block must also be moved and installed. When

installed to the wall, make sure that the screws completely

VERIFYING PACKAGE

CONTENTS

• Remove all packing materials from inside the

drawer. DO NOT REMOVE THE WAVEGUIDE

COVER, which is located inside, on the ceiling of

the Microwave In-A-Drawer™.

Waveguide

Cover

Sealing

Surface

• Remove the feature sticker, if there is one. Check

the drawer for any damage, such as misaligned or

bent drawer, damaged drawer seals and sealing

surfaces, broken or loose drawer guides and

dents inside the cavity or on the front side of the

drawer. If there is any damage, do not install or

operate the Microwave In-A-Drawer™ and contact

your dealer or a DACOR AUTHORIZED SERVICER.

Sealing

Surface

Oven

Cavity

Figure 7

ELECTRICAL OUTLET

4"

5"

electrical outlet

location

anti-tip

block

(6")

Figure 8

The electrical requirements are a 120 volt 60 Hz, AC

only, 15 amp. or more protected electrical supply. It

is recommended that a separate circuit serving only

this appliance be provided.

The drawer is equipped with a 3-prong grounding

plug. It must be plugged into a wall receptacle that

is properly installed and grounded. Should you only

have a 2-prong outlet, have a qualified electrician

install a correct wall receptacle.

NOTE:

If you have any questions about the grounding or

electrical instructions, consult a qualified electrician

or service person.

penetrate the dry wall and are properly secured into the

base material underneath so that the block is totally

stable. When fastening, be sure that the screws do not

penetrate electrical wiring or plumbing.

4"

5"

electrical outlet

location

anti-tip

block

(6")

Figure 6

Installation Instructions