beautypg.com

Enviro 828 DV.INS. User Manual

Page 3

background image

TABLE OF CONTENTS

1 Code Approvals ...........................................................................................................................................3

Specifications...............................................................................................................................................3
2 Dimensions and Clearances to Combustibles .............................................................................................4

Zero Clearance Box Assembly .................................................................................................................... 5

3 Deciding Where to Locate Your Stove .........................................................................................................6
4 Assembly Instructions ..................................................................................................................................6
Fireplace Insert ............................................................................................................................................ 7

5 Installing burner control assembly ............................................................................................................... 8

6 Installation of Log Sets and Embers.............................................................................................................8
7 Electrical Requirements ...............................................................................................................................9

8 Gas Line Connection....................................................................................................................................10
9 Air Shutter Adjustment .................................................................................................................................11
10 Venting........................................................................................................................................................12
11 Mobile Home Fuel Conversion....................................................................................................................19
12 Operating Instructions .................................................................................................................................20
13 Routine Maintenance ..................................................................................................................................21
14 Trouble Shooting.........................................................................................................................................22
15 Parts and Accessories ................................................................................................................................23
16 Warranty .....................................................................................................................................................24

17 Installation data sheet................................................................................................................................ 25

1. CODES AND APPROVALS

Direct Vent Type is designated by the suffix DV. This type of appliance draws all of the air for combustion from outside of the dwelling

through specially designed vent pipe.

These appliances have been tested by International Approval Services and found to comply with the established standards for DIRECT
VENT WALL FURNACES in CANADA and the USA as follows:

LISTED GAS FIRED GRAVITY DIRECT VENT WALL FURNACE ( 828 DV. Nat. & LPG. )

TESTED TO: ANSI Z21.44-1991 GAS FIRED FAN TYPE DIRECT VENT WALL FURNACE. CAN/CGA 2.19-M81 GAS FIRED GRAVITY
AND FAN TYPE DIRECT VENT WALL FURNACE. CGA INTERIM REQUIREMENT NO. 41-1991 DIRECT VENT GAS FIREPLACES
CGA INTERIM REQUIREMENT NO. 55 - ADDITION REQUIREMENTS FOR DIRECT VENT FIREPLACES. CGA 2.17-M91 GAS FIRED
APPLIANCES FOR USE AT HIGH ALTITUDE

2

ENVIROGAS 828 DIRECT VENT UNITS;

Have all been certified for use with either natural or propane gases. (See control panel and rating label.)

Are not for use with solid fuels.

Are approved for bedroom or bedsitting room.

Must be installed in accordance with local codes if any. If none exist use current installation code CAN/CGA B149 in Canada or ANSI
Z223.1 / NFPA 54 in the USA.

Must be properly connected to an approved venting system.

Manufactured (mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL
307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A. The unit must be
bolted to the floor of the mobile home and must be electrically grounded to the steel chassis.

FREESTANDING;

Are approved for installation on combustible materials.

Are not approved for closet or recessed installations.


INSERT;

are for installation in solid fuel burning fireplaces only;

can be installed in Envirogas Zero Clearance Can kit 828-134 as a zero clearance unit.

3

This manual is related to the following products: