beautypg.com

Burner lighting, Turn off unit, Remote controls - optional – Enviro C-10637 User Manual

Page 8: Blower speed, Operating instructions

background image

8

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

A) Make sure the pilot is lit.

B) Turn gas control knob COUNTER CLOCKWISE to ON.

C) Flip the burner switch to ON.

D) Turn HI/LO knob to the desired flame height.

E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.

T

URN

O

FF

U

NIT

:

Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If

the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF,

for the first two to four hours. This will cure the paint, logs, gasket material, and other products used

in the manufacturing process. It is advised that a door or window be opened, as the unit will start to

smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF,

including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good

gas fireplace glass cleaner, available at your local Enviro dealer. See “D

OOR

R

EMOVAL

” and “C

LEANING

T

HE

G

LASS

” sections.

R

EMOTE

C

ONTROLS

- O

PTIONAL

:

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of

these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the

control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall

thermostat for operation guidelines.

B

LOWER

S

PEED

:

The blower will come on only when the fireplace is up to temperature (approximately

20 minutes). Turning the fan control knob will change the speed of the fan. To turn

the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off (Figure 6).
It is advisable not to operate the blower below

1

/

3

speed as it puts a strain on the

windings of the blower and running the blower at lower speeds could also cause

premature fan failure.

��

���

��

Figure 5. Control panel.

Figure 6. Fan control.

B

URNER

L

IGHTING

: