Operating instructions, Pilot lighting instructions, Pilot light – Enviro C-10637 User Manual
Page 7: Caution
7
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION
MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
P
ILOT
L
IGHTING
I
NSTRUCTIONS
:
Figure 3. Lighting instruction label.
1. STOP! Read the safety information above on this label.
2. Turn off all electrical power to this appliance.
3. Turn off the gas control knob clockwise
to the off position.
4. Open door. Wait fIve (5) minutes to clear out any gas. Close door. If
you smell gas STOP! Follow “B” in the above safety information. If
you do not smell gas go to the next step.
5. Find pilot-located to the left under the front log. Turn the gas control
knob counter-clockwise
to “PILOT”. Push the gas control in fully
and hold, keep knob depressed for about 30 seconds after
the pilot is lit. Release knob. If pilot goes out, repeat
steps 4 through 5.
CAUTION:
Hot while operating. Do not touch, severe burns may result. Keep children, clothing,
furniture, gasoline or other flammable vapors away.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A) This appliance is equipped with a pilot, which must be lit by hand by
following these instructions exactly.
B) BEFORE LIGHTING smell all around the appliance area for gas and next to
the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance. Do not touch any electrical switch: do not
use any phone in your building. Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppliers instructions. If you cannot reach
your gas supplier, call the fire department.
C) Use only your hand to push in or turn the gas control knob;
NEVER use tools. If the knob will not push in or turn by hand, do
not try to repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING: this gas valve has a lockout device, which will not allow the
pilot burner to be relit until the thermocouple has cooled. If the knob does
not pop up when released, stop and immediately call your service
technician or gas supplier.
If the pilot does not stay lit after several tries, turn the gas control knob
to “OFF” and call your service technician or gas supplier.
6. Turn the gas control knob counter clockwise
to the “ON”
position. Flip the burner switch to “ON” THEN TURN THE “HI/LOW”
knob to the desired setting.
7. Turn on the electrical power to the unit.
TO TURN OFF GAS TO APPLIANCE
1. Flip burner switch to “OFF”
2. Turn the gas control knob clockwise
to the “OFF” position.
�������
3. Turn off all electrical power to the appliance if service is to be performed.
CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or
qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See
installation and operating instructions manual. Keep burner and control compartment clean.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's
information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency,
or the gas supplier.
O
L I
T
P
TP
TH
TP
TH
IN
OU
T
H
I
LO
N
OF
O
F
LI
P
T O
P
ILOT
L
IGHT
:
1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out
for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints
with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING.
2. Start the pilot by pressing the gas control knob and turning it to PILOT.
While holding the gas control knob in, press the piezo ignitor several times
until the pilot light starts. Hold the gas control knob in for 30 seconds.
Check that the pilot has fully engulfed the thermocouple assembly (see
Figure 4).
3. Start the main burner by turning the gas control knob to ON and then turn
the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
����������
������������
Figure 4. Pilot flame.
Operating Instructions
For Your Safety, Read Safety Precautions And