Initial Installation

QUALIFIED INSTALLERS ONLY

E

LECTRICAL

R

EQUIREMENTS

:

Fan Control

Black

White

White

Black

Green/Yellow

Green

Black

Power Cord

120V AC

FAN

120

o

F (49

o

C)

Temperature Sensor

CNT2

CNT3

CNT1

CNT4

The fan is thermostatically controlled and it will

not operate if the appliance is cold. A few minutes

after the appliance is lit and the variable speed

control is set at a desired setting, the fan will

automatically turn on. The fan will automatically

turn off after the appliance has cooled down.
The fireplace must be electrically connected and

grounded in accordance with local codes or, in the

absence of local codes, with the current CSA C22.1

Canadian Electrical Code Part 1, Safety Standards

For Electrical Installations, or The National

Electrical Code ANSI / NFPA 70 in the US.

WARNING: The electrical grounding instructions

must be followed. The fan kit is equipped with a

three-prong (grounding) plug for your protection

against shock hazard, and should be plugged

directly into a properly grounded three-prong

outlet. DO NOT cut or remove the grounding

prong from this plug.

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

70 ° F

ON

OF

F

Optional

Remote

Control

Purple

Grey

Optional

Wall Switch

Optional

Thermostat

Pilot

Adjustment

Screw

ON/OFF/REMOTE

Thermostat Switch

Blue

Thermopile

Thermocouple

Manifold

Pressure

Tap

Inlet

Pressure

Tap

Gas

Control

Valve

Blue

BV Only

300

o

F (149

o

C)

Temperature

Sensor

(DV has only

connectors)

Figure 14: Wiring of a valve and thermostat.

Table 3. Recommended Thermostat

Wire Size.

Figure 13: Fan wiring diagram.

CAUTION: When servicing controls,

label all wires prior to disconnection.

Wiring errors can cause improper

and dangerous operation. Verify