beautypg.com

2 power supply cable wiring – Epson FEH300b User Manual

Page 37

background image

3-3

• Tighten terminal screws on the power supply terminal block of the display unit with the following torque.

Use a power supply cable within the range shown below.

Types

Tterminal screw

Power

Cable

Screw

size

Tightening

torque

Crimp-style terminal

NP5M0101-5H4
NP5M0101-4H4

NP5N0011-5H4
NP5N0011-4H4

M3.5

0.8N· m

AWG18 - 16

NP5M0101-3H4

NP5N0011-3H4

M3.5

1.2N· m

AWG16 - 14

• The power supply terminal block of the controller unit uses M3 terminal screws. Their tightening torque should be

0.5 to 0.6 N·m.
Select the appropriate cable, and crimp terminals to be used. Applicable cable sizes and crimp terminals are as
follows:

Maker

Form

Types

Cable size

AWG

mm

2

AMP

Round
terminals

36467

22 to 18

0.3 to 0.8 mm

2

34104

34105

Nichifu

Round
terminals

0.3-3

24 to 20

0.2 to 0.5 mm

2

0.3-3N

1.25-3

22 to 16

0.3 to 1.3 mm

2

1.25-3N

1.25-3S

1.25-3.5N

1.25-3.5S

2-3N

16 to 14

1.3 to 2.0 mm

2

Angle edge
terminals

0.3Y-3

24 to 20

0.2 to 0.5 mm

2

1.25Y-3

22 to 16

0.3 to 1.3 mm

2

1.25Y-3N

1.25Y-3S

1.25Y-3.5

2Y-3

16 to 14

1.3 to 2.0 mm

2

2Y-3.5S

AT1-10

22 to 16

0.3 to 1.3 mm

2

AT2-10

16 to 14

1.3 to 2.0 mm

2

JST

Round
terminals

SRA-20-3.2

22 to 18

0.3 to 0.8 mm

2

SRA-20T-3.2

NTK

Round
terminals

0.4-3

26 to 22

0.2 to 0.3 mm

2

1.25-3

22 to 16

0.3 to 1.3 mm

2

Angle edge
terminals

VR1.25-3

VD1.25-3

VD2-3S

16 to 14

1.3 to 2.0 mm

2

7.6

6

Terminal dimensions

3-2 Power Supply Cable Wiring

φ

3.7mm

8mm

or less

3.7mm

8mm

or less

3.7mm

7.1mm

or less

φ

3.7mm

7.1mm

or less