2 power supply cable wiring, 1) power supply cable wiring, Warning – Epson FEH300b User Manual

Page 36: 24v dc + - fg

background image

3-2

3-2 Power Supply Cable Wiring

Warning

Electric shock hazard.
Shut the power off before wiring the power supply cable.

(1) Power supply cable wiring
Power supply terminal blocks of the display unit and the controller unit are connected with each other with a cable by
default. Use one power supply terminal block to connect the power supply cable.

• For NP5M0101-5H4/4H4

NP5N0011-5H4/4H4

CN5

CN7

CN1

24VDC

FG

CN5

LAN

U-B

U-A

CN7

CF

MJ1

MJ2

4:RUN
3:U-TERM
2:TERM
1:STOP

ONL
ERR
UROM
RUN
ALM
BAT

No.

USB

LOADER

USER ROM CARD

CPU

SX-BUS

IN

OUT

24V DC

+

-

FG

U-A

U-B

LAN

CN1

MJ2

MJ1

CF

4:RUN
3:U-TERM
2:TERM
1:STOP

ONL
ERR
UROM
RUN
ALM
BAT

No.

USB

LOADER

USER ROM CARD

CPU

SX-BUS

IN

OUT

24V DC

+

-

FG

Power supply

Grounding

24V DC

+

-

FG

Power
supply

Grounding

24V DC

+

-

FG

• Attaching noise filter
Attach accompanying noise filter to the power supply cable between the DC power supply and the power supply terminal
block.

Do not bundle up and do not close.

DC power
supply

@E.terminal side

Noise filter
(accessory)

Keep the distance between the DC power supply
and the power supply module as short as possible,
and the cable must be twisted densely.

24V DC

+

-

FG

* Noise filter is not required for controller unit hardware version “03” or later.

Noise filter is not attached as accessory with above version.

Connect the power supply cable to the power
supply terminal block of the controller unit.

Connect the power supply cable to the power
supply terminal block of the display unit.

• For NP5M0101-3H4

NP5N0011-3H4