1200 bps, Evf - 1, Pelco-d – EverFocus SPEED DOME EPTZ1000 User Manual
Page 17: Pelco-p, Type-a, Communication protocol setting the 1, And 3, And 5
2-16
2.3.2. Communication Protocol Setting
The 1
st
, 2
nd
and 3
rd
bits of the SW2 are used to set communication protocol. The factory
default protocol is EVF.
ON
1234
567
8
SW2
Protocol
Baud Rate
PAL / NTSC
Maching Resistance
ON
123
4
567
8
EVF - 1
ON
123
4
567
8
PELCO-D
ON
123
4
567
8
PELCO-P
ON
123
4
567
8
TYPE-A
Notice: Please make sure the power is off before setting, and restart the speed dome to
enable a new value after changing.
Set all of protocol switches to ON; the EPTZ1000will enter a self-test mode.
2.3.3. Transmission Speed Setting (Baud Rate Setting)
The 4
th
and 5
th
bits of the SW2 on the PCB board are used to set the Baud Rate. The
default baud rate setting is 9600.
ON
1
2345
678
SW2
Protocol
Baud Rate
PAL / NTSC
Maching Resistance
ON
12
3
45
678
9600 BPS
4800 BPS
2400 BPS
ON
12
3
45
678
ON
12
3
45
678
1200 BPS
ON
12
3
45
678
Notice: Please make sure the power is off before setting, and restart the speed dome to