43BDL4550D_50BDL4550D_55BDL4550D

47

• {Playlist} – Select playlist index for MediaPlayer,

Browser, PDF Player. 0 indicates there is no playlist.

WOL (Wake on LAN)

Allow the display to be turned on by a network message.
Note: This function only works in power mode 1 and mode 2.

Light sensor

Choose to turn on or off the light sensor function of CRD41.

Human sensor

Choose to turn on or off the human sensor function of
CRD41.

Configuration 1 reset

Reset all settings in Configuration 1 menu to factory preset
values.

Factory Reset

Reset all customized settings in Picture, Screen, Audio,
Configuration 1, Configuration 2 and Advanced Option to the
factory default values.

6.2.5. Configuration 2 menu

Picture
Screen
Audio
Configuration 1
Configuration 2
Advanced option

OSD turn off
OSD H position
OSD V position
Rotation
Information OSD
Logo
Monitor ID
Heat status
Monitor information

DP Version
HDMI Version

Configuration2 reset

45
50
50
Landscape
10
On
Action
24.21°C 75.57°F
Action

Action

OSD turn off

Set the period of time the OSD (on-screen display) menu
stays on the screen.
The options are {Off, 5 - 120} seconds. {Off} does not
disappear automatically.

OSD H position

Adjust the horizontal position of the OSD menu.

OSD V position

Adjust the vertical position of the OSD menu.

Rotation

Change OSD and Android to Landscape / Portrait mode.
Note: Video inputs will not rotate with this setting.
Note: If Android APK plays video content, user MUST stop
and re-play to get correct video image.

Information OSD

Set the period of time the information OSD display on the
upper left corner of the screen. The information OSD will
display when input source and signal are changed.
The options are {Off, 1 - 60} seconds.

Logo

Choose to enable or disable the picture of Logo when
turning on your display.

• {Off} – Both static Philips logo and Android boot

animation will not be shown.

• {On} – Default value. Both Philips logo and Android boot

animation will be shown.

• {User} – Static Philips logo will not be shown, only

user-selected boot animation will be shown in Android
settings.

Note: Logo will not be rotated even thought rotation setting
is set.

Monitor ID

Set the ID number for controlling the display via the RS232
connection. Each display must have a unique ID number
when multiple sets of the display are connected. Monitor ID
number range is between 1 and 255.
• {Monitor ID} set range in {1-255}. The default setting is 1.
• {Monitor group} set range in {1-254}. The default setting

is 1.

Heat Status

Current thermal status.

Monitor information

Shows information about your display, including model
name, SW version, serial number, and operation hours.

Monitor information

Model name
Serial NO.
Operation hours
SW Version

N/A
0
FBXX.XX

DP version

Change DP version. 1.1 or 1.2.

HDMI version

Set the HDMI version to 1.4 or 2.0.
Note: HDMI input source only.

Configuration 2 reset

Reset all settings in Configuration 2 menu to factory preset
values.

6.2.6. Advanced Option menu

Picture

Screen

Audio

Configuration 1

Configuration 2

Advanced option

IR control

Power LED Light

Keyboard control

Tiling

Off Timer

Date and time

Schedule

HDMI with One Wire

HDMI One Wire Power off

Auto signal detection

Language

OSD transparency

Unlock

On

Unlock

Action

Off

Action

Action

Off

Off

Off

English

Off

IR control

Select the operation mode of the remote control when
multiple displays are connected via RS232 connection.