Water-stop device, Water drainage – Electrolux 63742 VI User Manual

Page 39

background image

4. Connect the hose to a tap with a 3/4” thread.

Always use the hose supplied with the appliance.

Installation should comply with local water authority
and building regulations requirements. A minimum
water pressure of 0.05 MPa is required for safe
operation of the appliance.
If you cannot make the cold water connection direct
from the rising mains, you may be able to operate the
appliance from your cold water storage system. There
should be a minimum vertical distance of 5.02m (16.5ft) between the appliance’s
inlet and the bottom of the water storage tank.

Water-stop device

The inlet hose is provided with a water stop device,
which protects against damage caused by water
leaks in the hose which could develop due to
natural ageing of the hose. This fault is shown by a
red sector in the window “A”. Should this occur, turn
the water tap off and refer to your Service Centre
to replace the hose.

Water drainage

This appliance is designed to be permanently plumbed into your home's drainage
system using one of the following methods.

1. Into a drainage standpipe.

Firstly form a hook in the end of the drain hose using
the “U” piece” supplied.

Place the drain hose into your standpipe, which
should have an internal diameter of
approximately 38mm thus ensuring
there is an air break between the
drain hose and standpipe.

39

Installation

A

352

P1199

“U” piece

supplied

30 cm (12")

38 mm (1.5”)

standpipe

diameter

132963770_en.qxd 21/07/2008 8.25 Page 39